Lock Behaviour
Security Lockout
After several incorrect PIN code or RFID attempts, the corresponding entry method will be
locked out and the security alarm will be triggered.
Note: You may attempt other methods of entry (Bluetooth unlock, manual unlock via Multi-
Function button etc.) to override the lockout mode.
Triggered by
Disabled by
Behaviour
Duration
Triggered
1st Time
2nd Time
3rd and
Consecutive Time
Security Lockout
5 consecutive invalid PIN or RFID attempts
by default (Configurable via Bluetooth)
After 1 / 5 / 10 Minutes
or
Any other unlocking methods
If keypad is disabled -
single flash when keypad is triggered
If RFID is disabled -
RFID reader will not read any RFID cards
Please refer to table below.
Security Alarm
30 Sec
60 Sec
90 Sec
Security Lockout
1 Min
5 Min
10 Min
27