Settings
Display, cont'd

Advanced Settings

Advanced settings
Night period
This is the time when you usually go to bed at night and wake
up in the morning. The brightness of "Night" mode will begin
and end using this time.
Screen lock
Locks the 6iE screen to prevent any unauthorised changes to
the 6iE. Requires a 4 digit code to access the menu or make
changes.
Sensors &
Application
14
Internal Air Sensor
Probe 1 Connected
The 6iE uses a 10K sensor. However, if using
a 6iE to replace an existing thermostat you
must change to the correct sensor type.
Probe 2 Connected
Swap Probe Usage
The function of Probe 1, Probe 2 from
Control/ Limit Sensor can be swapped here.
Floor
thermostat
(Probe 1 On, Probe
2 Off. See Table
1.0 for alternative
thermostat use
cases)
Choose to switch the method of control for
the sensor; floor sensor, remote air sensor
if not installed underneath the floor or
regulator mode.
Regulator Mode; Heating is on for X% out of
control cycle (default 10mins). Heating is off
for remaining time.
Floor type
*
Choose the floor type of your installation.
This will apply different temperature and
overheat limits to the 6iE.
*
Not applicable if conventional heating
system was selected.
Set the Start and
End period
On/Off
Offset
+/- 10°
On/Off
Type
5, 10, 15, 100K
Offset
+/- 10°
On/Off
Type
5, 10, 15, 100K
Offset
+/- 10°
Control
Floor
Remote Air
Regulator
Limit
None/Air
Tile/Stone
Laminate
Carpet
Wood
Vinyl
Other