Wiring Diagrams - Warmup 6iE User Manual

Hide thumbs Also See for 6iE:
Table of Contents

Advertisement

Wiring Diagrams

Heating Load connected to 6iE and Relay 25 - Max. 40 Amps
L1-LOAD-L2
HEATING
(MAX 3600W/
15 Amps)
N.B.
Heating loads connect to Relay-25
N.B.
and 6iE:
Relay-25
6iE
Total
Heating Load connected to Relay 25 - Max. 25 Amps
L1-LOAD-L2
HEATING
(MAX 3600W/
15 Amps)
Snubber
(contact suppressor)
240V SUPPLY WITHOUT GFCI
PROTECTION
L1-LINE
L2-LINE
L1-LINE-L2
POWER
SUPPLY
Max load 25A
Max load 15A
Max load 40A
Snubber
(contact suppressor)
240V SUPPLY WITHOUT GFCI
PROTECTION
L1-LINE
L2-LINE
L1-LINE-L2
POWER
SUPPLY
N.B.
All heating loads connect to Relay-25
only, controlled by 6iE
Hot (240V)
Hot (240V)
240V GFCI
PROTECTED SUPPLY
Hot (240V)
Hot (240V)
Hot (240V)
Hot (240V)
240V GFCI
PROTECTED
SUPPLY
Hot (240V)
Hot (240V)
6
240V
COIL SUPPLY
0
1
2
4
6
8
Heater(s)
Max 25A
Heater(s)
Max 15A
COIL SUPPLY
0
2
4
6
Heater(s)
Max 25A
240V
1
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6ie-04-cw-lc

Table of Contents