7. Write down on a piece of paper AND GIVE TO THE
OWNER a list showing what rooms are controlled by what
dampers, and their corresponding zone numbers. Keep list for
your future use.
8. Instruct owner to turn cool switch OFF in the fall, and turn it
ON in the spring.
9. Make sure emergency heat switch is in the OFF position. If a
gas furnace is used this switch should never be turned on. It is
for heat pumps only.
10. Be sure and set clock to correct time of day. You only need to
do this when you first power up system, or after a power
outage lasting longer than 8 hours.
11. Go to rotary switch setting 2 on the 4 zone controller. Check
calibration of room sensor. Do same for zones 2, 3, and 4
(rotary switch 3-4-5). Sensors must be calibrated.
12. Instruct owner in operation of Comfort Zone System
CONTROLLER DISPLAY
INDICATES ZONE SETPOINTS, ZONE TEMPERATURES,
AND PROGRAMMING INFORMATION AND
ALLOWS SETPOINT ADJUSTMENT.
FOUR
ZONE
OPTIONS
9
8
CONTROLLER
7
6
5
4
3
OPTIONS
8
7
6
5
4

ZONE SELECTOR DIAL

PROVIDES ACCESS TO INFORMATION AND PROGRAMMING
FOR EACH ZONE AND SELECTION OF VACATION MODE.
OPTION AREA IS FOR USE BY INSTALLATION/SERVICE.
8
T
SET
ZONE 1
SELECT
TIME/TEMP
MIN/HR/DAY
SCHEDULES
ZONE 2
HOLD
ADVANCE
ZONE 3
TEMPERATURES
TIME/DAY
OFF AUTO
AUTO OFF
AUTO
ON
OFF
ON
ZONE 4
HEAT
COOL
FAN
EMERGENCY HEAT
1
VACATION
2
S
9
T
ZONE 1
ZONE 2
ZONE 3
ZONE 4
3
1
VACATION
2
Fig. 18—Four Zone Controller
13. Instruct owner to call 800 number supplied with Comfort Zone
Center to receive free "How to use Comfort Zone" video tape.
14. For toggle settings for configuration see Programmable
Toggles and Options and Table 9.
Step 14—Programming Schedules
The 4 zone controller is the program center for the Comfort Zone
System. The 4 zone controller provides the ability to program
system for unique demands of each zone at different times during
the day and week. See Fig. 18 to become familiar with various
parts of the 4 zone controller.

SYSTEM SWITCHES

System switches select desired equipment operation.
Heat Switch
OFF—Heat will not come on.
AUTO—Heat will come on when any zone is more than 1.5°F
below desired heat setpoint.
INDICATES THE CURRENT TIME AND DAY
AND THE START TIMES/WEEKLY PERIODS
AM
PROGRAMMING ADJUSTMENT BUTTTONS
ALLOWS FOR PROGRAMMING WEEKLY PERIODS, START TIMES
FOR EACH ZONE AND SETS THE CLOCK FOR DAY AND TIME.
OFF AUTO
HEAT
PROVIDES FOR SELECTION OF HEAT, COOL,
FAN AND EMERGENCY HEAT OPERATION.
14
CLOCK DISPLAY
DURING PROGRAMMING.
AM
SET
SELECT
TIME/TEMP
MIN/HR/DAY
SCHEDULES
HOLD
ADVANCE
TEMPERATURES
TIME/DAY
AUTO OFF
AUTO
ON
OFF
ON
COOL
FAN
EMERGENCY HEAT
!
SYSTEM SWITCHES
A93232