Connecting The Kd Supply 2500 To The Cooling Unit And Power Source; Safety - Fronius KD Supply 2500 Operating Instructions Manual

Hide thumbs Also See for KD Supply 2500:
Table of Contents

Advertisement

Connecting the KD Supply 2500 to the cooling unit
and power source

Safety

Danger from electrical current.
This can result in serious personal injury and damage to property.
Connecting the
KD Supply 2500
to the cooling
unit and power
source
(1)
(1)
(2)
(2)
Risk of short circuit from kinked or damaged cables.
This can result in serious personal injury and damage to property.
WARNING!
Before starting work, switch off all devices and components involved and disconnect
them from the grid.
Secure all devices and components involved so they cannot be switched back on.
After opening the device, use a suitable measuring instrument to check that electric-
ally charged components (such as capacitors) have been discharged.
CAUTION!
When positioning the KD Supply 2500, ensure that the cables are not kinked.
Turn the power source mains switch to
1
the „O" position
Unplug power source mains plug
2
Remove protective cover from the un-
3
derside of the power source
Firmly press four M5 hexagonal nuts
4
(supplied with the KD Supply 2500)
from the inside into the hexagonal re-
cesses (1) in the fastening bars
If a cooling unit is present:
Remove the protective cover from the
5
(1)
underside of the KD Supply 2500
(1)
FIrmly press four M5 hexagonal nuts
6
(supplied with cooling unit) from the in-
side into the hexagonal recesses (2) in
the fastening bars
Hold the KD Supply 2500 over the
7
cooling unit
Pull the KD Supply 2500 connector as
8
far as possible through the opening on
(2)
the underside of the power source
(2)
Establish connection between KD
9
Supply 2500 and cooling unit
9

Advertisement

Table of Contents
loading

Table of Contents