OneAdvisor-1000 Portable Network Tester
QUICK CARD
R U N T E S T
Press the Start soft key
1.
After auto-configuration, the OTDR will perform
a connection check to ensure that the
connection is Good. If the Connection is Bad,
disconnect the launch cable, and reconnect as
described on pages 1 and 2, cleaning every fiber
that fails the inspection test.
The OTDR will perform an acquisition at the
2.
configured wavelength.
V I E W S M A RT L I N K M A P
Tap the SmartLink tab at the left screen top to
1.
select SmartLink view.
Set the toggle switch at the right screen top to
2.
Event Line.
View SmartLink results:
3.
The FUT is displayed as a series of icons
representing events (front connector,
launch cable, connectors, splices, bends,
etc.) and distances. Swipe left or right to
view additional icons on spans with more
than 4 events.
The center of the display shows summary
results for the entire span for each
acquisition or wavelength. Tap any event
in the upper display to view detailed results
for that specific event.
Events are marked with a green check or
red
x
based on the Alarms setting.
Note: the icon-based view may not be
available on older ONA-1000s when
acquisition Mode = SmartAcq. Rerun the test
with Mode = Auto or contact VIAVI to upgrade
your unit to add this feature.
OneAdvisor-1000 Portable Network Tester
to start the test.
VIAVI//Public
Figure 10: Connection Check
Figure 11: SmartLink View, Summary Results
Figure 12: SmartLink View, Event Results
4