3.6. Installing the Heater

See figure 6-7.
1. Connect the supply cable (fig. 7:1) to the heater.
2. Install the wall mount horizontally to the wall
using suitable fasteners. Make sure that the heater
is supported not only by the wall panel (figure 6).
Take note of the floor's slope. Using the wall mount
ensures the 80 mm safety distance.
3. Lift the heater into the mount and make sure it is
centered (figure 7:3). Install mounting bracket (A)
and pile the sauna stones (B) according to instruc-
tions ( 1.1.).
4. Install the safety guard (fig 7:4:1) and steam
guide (7:4:2-3) to the heater and the wall mount.
5. Secure the heater to the wall mount by screwing
two screws behind the steam guide (figure 7:5).
Figure 8. Reset button for overheat protector.
14

3.7. Resetting the Overheat Protectors

If the temperature of the sauna room becomes
dangerously high, the overheat protector will
permanently cut off the supply of the heater. The
overheating protectors can be reset after the heater
has cooled down. See figure 8. Please check that the
stones are piled properly and the sensor is installed
according the installation instructions.
The reason for overheating must be resolved
before resetting the overheat protector!
Overheat protector of the device can go off
!
also at temperatures below -5˚C / 23˚F
(storage, transport, environment). Before
installation take the device to the warm environ-
ment. The overheat protector can be reset when the
temperature of the device is approx 18˚C / 64˚F.
The overheat protector must be reset before using
the device