3.5 E
NVIRONMENTAL
The Mini-Repeater is designed for indoor installation. It meets the European
IP54 standard for indoor equipment.
Condition
Operating temperature
Storage temperature
3.6 C
ONNECTORS
The Repeater interfaces with a Base antenna port and a Mobile antenna port
(see Figure 4). It includes six external connectors in its bottom panel, as
described below.
RF Connectors: BASE / MOBILE
DC Power (9 V)
Communications
Coupling Connectors (-20 dB):
Base / Mobile
Alarms
Figure 4: Mini Repeater – Connectors Panel
Page 10
M
R
INI
EPEATER
S
PECIFICATIONS
Connector
Proprietary Data
D
2408-09
D
EKO
EKOLINK
Value
-20 °C to +50 °C
-30 °C to +80 °C
Type
N-type, Female
Circular DIN, 4-pin
RS-232
SMA
Dry Contacts- 3 pins;
Normally close (NC),
Common,
Normally Open (NO)
Pub. 308-2005 Rev. 2.00S