Dekolink DEKO2408 Product Manual page 47

High selectivity mini-repeater
Table of Contents

Advertisement

D
W
L
EKOLINK
IRELESS
7.5.2 Link Alarms
The Power Amplification alarms are provided for the Downlink and the Uplink
paths.
The troubleshooting procedures for these alarms follow.
Figure 28: Mini-Repeater - Link Alarms
7.5.2.1 PAmp FWD Measure
This LED is linked with the upper Amp FWD (forward) Threshold combo box.
This LED shows malfunction in the Downlink path (there is no Uplink
malfunction linked to this feature).
Most probable cause: Output power is less than minimum threshold limit. .
Corrective action: Check the Max Power Value in the Controls and
Parameters screen. If the value is lower than the value in the Amp FWD
(forward) Threshold combo box in the Alarms screen, select a lower value
in this screen.
7.5.2.2 PAmp Current
This LED shows malfunction similarly for the Downlink and Uplink paths.
Most probable cause: Downlink (Uplink) power amplifier module outputs
a low current.
Corrective action: Check the LEDs in the Mini-Repeater. See
paragraph 7.4.
7.5.2.3 Channeler Current
This LED shows malfunction similarly for the Downlink and Uplink paths.
Most probable cause: Downlink (Uplink) channeler module outputs a low
current.
Corrective action: Check the LEDs in the Mini-Repeater. See
paragraph 7.4.
7.5.2.4 RSSI
This LED shows malfunction similarly for the Downlink and Uplink paths.
Most probable cause: Downlink (Uplink) input signal is high.
Corrective action: Check the LEDs in the Mini-Repeater. See
paragraph 7.4.
Pub. 308-2005 Rev. 2.00S
.
M
R
TD
INI
EPEATER
Proprietary Data
D
2408-09
EKO
P
M
RODUCT
ANUAL
Page 39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deko2409