3.2 FBDA ALARM SPECIFICATIONS

RemoteFault
Indication
(Summarized
alarm)
Fault List :
Electrical Fault
Indication LED
Fiber Optic
Connection Fault
Indication LED
FBIU alarm
output

3.3 MECHANICAL SPECIFICATIONS:

FBDA
Size
400 x 400 x 300 mm approx.
Weight
25 kg. Approx.
Type
Weatherproof Enclosure
Wall Mounted Installation
Power Supply
110 VAC / 2A or 220VAC/1A -48V DC 1A

3.4 ENVIRONMENTAL CONDITIONS:

Operating temperature
Storage temperature
Weatherproof conditions
FO-50W SYS
Dekolink WIRELESS Ltd.
16 Bazel St. Qiryat-Arieh Petah-Tikva, Israel, 49510
Tel- 972-3-9180-180 Fax-972-3-
e-mail:
Alarm is sent on the serial data link of the FO transmitter
to FBIU
Power Supply Over-voltage or Under-voltage
Uplink Amplifier Over Current or Under Current
Downlink Power Amplifier Over Current or Under Current
FO Transceiver Over Current or Under Current
FO Receiver Power fall (Bad Optical Connection)
Fan Over Current or Under Current
Illuminated LED on Monitor Box for each Electrical Fault
Illuminated LED on FO Transceiver when Optical
Connection is performing Correctly.
LED is OFF when FO Receiver Power falls.
D type 9pin male, N.C. relay contact between pin 2 and pin
4, open for active alarm + Illuminated LED on front panel.
°
- 30
C to + 50
°
- 30
C to + 70
Protected to IP65 (FBDA only)
9180
marketing@dekolink.com
web
FBIU
19" 1Ux250mm
3 kg. Approx.
for
In door, rack mount
Molex 2.13 mm , 3 circuits
female, male pins
°
C
°
C