Troubleshooting - Project Food AKD200R Installation, Operating And Service Instructions

Table of Contents

Advertisement

Available languages

Available languages

7. Troubleshooting

PROBLEM
Insufficient cooling
power
Not cooling
The appliance leaks
water (only versions
R, R SS and RG)
Very noisy
The compressor does
not shut off
automatically
The above cases are presented merely as examples of possible problems. In the event of any
problem, immediately switch the appliance OFF and contact the dealer.
The following characteristics are normal and do not represent malfunctions:
At regular intervals the temperature indicated on the digital control unit display increases by
4-5 degrees with respect to the set-point and then decreases: this is part of the normal
cooling cycle of any refrigerating appliance. See the detailed explanation in sect. 5.4.
The sound of flowing water. This sound occurs during normal use. It is the sound of the
coolant expanding inside the cooling circuit.
When there is high humidity, condensate on the internal part of the door is normal. Remove
the condensate by wiping it off with a soft cloth.
Requesting spare parts:
To request spare parts, contact the dealer and refer to the part number indicated in
the spare parts drawings at the end of this handbook (Section 11), also indicating the
appliance's model and serial number.
29
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
CAUSES
 Direct sunlight or near heat sources.
 Control unit is performing a defrost
cycle.
 The door is not completely closed or
has been opened too long.
 The door seal is damaged or
deformed.
 The evaporator is covered in ice.
 Dirty condenser coil.
 The electric plug is not inserted in the
socket.
 The compressor does not turn on.
 Power failure
 The water elimination device is
damaged, the discharge has not been
well channeled or is blocked.
 The appliance is not positioned on a
flat surface or the legs are not
properly adjusted.
 The appliance is not positioned on a
flat surface or the legs are not
properly adjusted.
 There is a vibration caused by loose
screws or bolts.
 Too many products inside the
appliance.
 The door is not closed or has been
opened too long.
SOLUTION
 Move the appliance away from the heat
sources.
 Wait for the control unit to complete
the defrost cycle (max. 20 minutes).
 Close the door completely, keep the
door open for shorter periods of time.
 Contact the dealer.
 Check that the door and the gasket seal
well and that no hot food has been put
inside the appliance. Contact the dealer.
 Clean the condenser coil (see section 6
"Cleaning and servicing").
 Insert the electric plug in the socket.
 Contact the dealer.
 Check the power supply.
 Make sure that the water elimination
device is well channeled and the
discharge is not blocked.
 Place the appliance on a flat surface and
adjust the legs so that the appliance
rests solidly on the ground.
 Place the appliance on a flat surface and
adjust the legs so that the appliance
rests solidly on the ground.
 Check that the screws and bolts have
not become loose during operation or
transport.
 Remove excess products.
 Only open the door as long as necessary
and check that it is properly closed.