Heat-N-Glo GRAND-50 Installer's Manual
Hide thumbs Also See for GRAND-50:

Advertisement

Underwriters
Laboratories Listed
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo GRAND-50

  • Page 1 Underwriters Laboratories Listed This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
  • Page 7 MODEL GRAND-50 57 1/2 25 5/8 42 1/4 59 3/4 84 1/2 (1460mm) (651mm) (1073mm) (1518mm) (2147mm)
  • Page 8 THE FRAMING HEADERS MAY REST ON THE FIREPLACE STAND-OFFS. 12”X12” VENT FRAMING SHOULD BE FRAMING HOLE. CONSTRUCTED OF 2 X 4 LUMBER OR HEAVIER. NOTE: DIMENSIONS SHOWN IN INCHES...
  • Page 9 Vent system components Vent system termination kits...
  • Page 10 6-7/16" 6-5/32" (164 mm) (156 mm) 8-1/2" (216 mm) 8-1/2" 11-5/8" 11-1/16" (216 mm) (295 mm) 7-3/8" 5-7/8" (281 mm) 6-1/2" 5-1/16" (187 mm) (149 mm) (165 mm) (129 mm) 8-5/8" (220 mm) 8-5/8" 11-15/16" (220 mm) (303 mm) 47-3/4" (1.2 m) 35-3/4"...
  • Page 11 VERTICAL VENTING V (FT.) 30' MAX. (9.3 M)
  • Page 12 VENTING WITH ONE (1) 90° ELBOWS V (FT.) H (FT.) 3' MIN. (914 mm) 6' MAX. (1.9m) 4' MIN. (1.2m) 8' MAX. (2.4m) 5' MIN. (1.6m) 10' MAX. (3.1m) 6' MIN. (1.9m) 12' MAX. (3.6m) V + H = 30’ MAX. (9.3 m) Ratio V to H = 1:2 H = 20' MAX.
  • Page 13 VENTING WITH TWO (2) 90° ELBOWS V (FT.) H (FT.) 3' MIN. (914mm) 6' MAX. (1.9m) 4' MIN. (1.2m) 8' MAX. (2.4m) 5' MIN. (1.6m) 10' MAX. (3.1m) 6' MIN. (1.9m) 12' MAX. (3.6m) V + H + H = 30’ MAX. (9.3 m) Ratio V to H + H = 1:2 H = 20' MAX.
  • Page 14 VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 3' MINIMUM (914 mm) 6' MAXIMUM (1.9 m) 4' MINIMUM (1.2 m) 8' MAXIMUM (2.4 m) 5' MINIMUM (1.6 m) 10' MAXIMUM (3.1 m) RATIO V TO H = 1:2 V + V + H + H = 30’...
  • Page 15 STARTING STARTING COLLAR COLLAR STOVE STOVE SEALANT SEALANT BEAD BEAD FIRST FIRST 3/8" (9.5 mm) 3/8" (9.5 mm) VENT VENT COMPONENT COMPONENT 3/8 INCH (9.5 mm) 1 INCH (25.4 mm)
  • Page 19 JOIST CEILING NAILS (4 REQUIRED) CEILING FIRESTOP...
  • Page 20 NAILS (4 REQUIRED) RAFTER CEILING CEILING FIRESTOP...
  • Page 21 (184mm)
  • Page 22 openable fixed closed J or K =VENT TERMINAL 1 2 3 1 2 3 =AREA WHERE TERMINAL IS NOT PERMITTED 1 2 3 =AIR SUPPLY INLET 1 2 3...
  • Page 24 TERMINATION (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING.
  • Page 25 Step 4 The diagram below shows how to properly position, Positioning, level, and secure the fireplace. Leveling, and Securing the Fireplace 1. Place the fireplace into position. 2. Level the fireplace from side to side and from front to back. 3.
  • Page 27 USE A WRENCH ON SHUT-OFF VALVE WHEN TIGHTENING GAS LINE.
  • Page 29: Speed Control

    FAN WIRING DIAGRAM NOTE: IF ANY OF THE ORIGINAL WIRE NOTE: IF ANY OF THE ORIGINAL WIRE VARIABLE SPEED CONTROL AS SUPPLIED WITH THE APPLIANCE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 DEGREE C REPLACED WITH TYPE 105 DEGREE C RATED WIRE.
  • Page 30 NOTE: ALL DIMENSIONS SHOWN IN INCHES.
  • Page 35 Type of Fireplace Fireplace Maintenance Task To Maintenance Frequency Be Completed Replacing Once annually, Qualified Brush away loose ember material near Old Ember during the Service the burner. Replace old ember Material annual check-up Technician material with new dime-size and -shape pieces of Golden Ember (GE-93) and Glowing Ember (050-721).
  • Page 36 MAKE SURE THE FLAMES ARE STEADY - NOT LIFTING OR FLOATING. DSI IGNITION NOTE: FLAMES TOO CLOSE TO THE CERAMIC INSULATORS CAN CAUSE NUISANCE LOCKOUTS AND ELECTRODE FAILURE.
  • Page 39 PART PART DESCRIPTION PART NUMBER Trim Door DF-G50-CARCH Mesh Kit Mesh-G50 LOG #1 SRV570-700A LOG #2 SRV570-701 LOG #3 SRV570-702 LOG #4 SRV484-703 LOG #5 SRV446-706 LOG #6 SRV484-702 LOG #7 SRV484-701 LOGS (Complete) LOGS-G50...
  • Page 40 PART PART DESCRIPTION PART NUMBER Side Refractory SRV570-744 Back Refractory - Left SRV570-746 Back Refractory -Right SRV570-748 Back Refractory -Top SRV570-742 PART PART DESCRIPTION PART NUMBER Fan Kit GFK-230 GFK-160A Remote Control Kit RC-SMART Wall Switch Kit - Off White WSK-21 - White WSK-21-W...