WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 1998,
Heat-N-Glo, a division of Hearth Technologies Inc.
6665 West Highway 13, Savage, MN 55378
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,4 87; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Heat-N-Glo Fireplace
READ THIS MANUAL BEFORE INSTALLING OR
Please contact your Heat-N-Glo dealer for any
questions or concerns. For the number of your
nearest Heat-N-Glo dealer, please call 612-890-8367.
Installers Guide
OPERATING THIS APPLIANCE. THIS
INSTALLERS GUIDE MUST BE LEFT WITH
APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. RE-
FER TO THIS MANUAL. FOR ASSIS-
TANCE OR ADDITIONAL INFORMA-
TION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
This appliance may be installed in an
1.
aftermarket, permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
2. This appliance is only for use with the
type of gas indicated on the rating
plate. This appliance is not convertible
for use with other gases, unless a
certified kit is used.
Underwriters
Laboratories Listed
570-900-C 10/98

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo Grand-50

  • Page 1 Printed in U.S.A. Copyright 1998, Please contact your Heat-N-Glo dealer for any Heat-N-Glo, a division of Hearth Technologies Inc. questions or concerns. For the number of your 6665 West Highway 13, Savage, MN 55378 nearest Heat-N-Glo dealer, please call 612-890-8367.
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty. Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.
  • Page 3: Table Of Contents

    Appliance Certification ..........1 Installation Codes ........... 1 High Altitude Installations ........1 Section 2: Getting Started......2 Introducing the Heat-N-Glo Gas Fireplaces .... 2 Pre-installation Preparation ........2 Section 3: Installing the Fireplace ....4 Step 1 Locating the Fireplace ........ 4 Step 2 Framing the Fireplace ........
  • Page 4: Section 1: Approvals And Codes

    Approval Listings Appliance Certification and Codes Installers Guide Z21.50 • CGA2.22 Approvals and Codes Installation Codes High Altitude Installations...
  • Page 5: Section 2: Getting Started

    Introducing the Heat-N-Glo Fireplaces Installers Guide Getting Pre-installation Started Preparation Installers Guide...
  • Page 7: Section 3: Installing The Fireplace

    Step 1 Locating the Fireplace Installing the Fireplace MODEL GRAND-50 57 1/2 25 5/8 42 1/4 59 3/4 84 1/2 (1460mm) (651mm) (1073mm) (1518mm) (2147mm) Clearance Requirements...
  • Page 8: Step 2 Framing The Fireplace

    Step 2 Framing the Fireplace CAUTION MEASURE FIREPLACE DIMENSIONS, AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS, BEFORE FRAMING CONSTRUCTION BEGINS. THE FRAMING HEADERS MAY REST ON THE FIREPLACE STAND-OFFS. 12”X12” VENT FRAMING SHOULD BE FRAMING HOLE. CONSTRUCTED OF 2 X 4 LUMBER OR HEAVIER.
  • Page 9: Step 3 Installing The Vent System

    A. Vent System Approvals Step 3 This model is approved to use D-Series comp Installing the Vent System Installers Guide. Identifying Vent Components WARNING: A 3-FOOT LENGTH OF STRAIGHT PIPE (MINIMUM) MUST BE THE FIRST VENT COMPONENT ATTACHED TO THE UNIT. Vent system components Vent system termination kits...
  • Page 10 6-7/16" 6-5/32" (164 mm) (156 mm) 8-1/2" (216 mm) 8-1/2" 11-5/8" 11-1/16" (216 mm) (295 mm) 7-3/8" 5-7/8" (281 mm) 6-1/2" 5-1/16" (187 mm) (149 mm) (165 mm) (129 mm) 8-5/8" (220 mm) 8-5/8" 11-15/16" (220 mm) (303 mm) 47-3/4" (1.2 m) 35-3/4"...
  • Page 11 VERTICAL VENTING V (FT.) 30' MAX. (9.3 M)
  • Page 12 VENTING WITH ONE (1) 90° ELBOWS V (FT.) H (FT.) 3' MIN. (914 mm) 6' MAX. (1.9m) 4' MIN. (1.2m) 8' MAX. (2.4m) 5' MIN. (1.6m) 10' MAX. (3.1m) 6' MIN. (1.9m) 12' MAX. (3.6m) V + H = 30’ MAX. (9.3 m) Ratio V to H = 1:2 H = 20' MAX.
  • Page 13 VENTING WITH TWO (2) 90° ELBOWS V (FT.) H (FT.) 3' MIN. (914mm) 6' MAX. (1.9m) 4' MIN. (1.2m) 8' MAX. (2.4m) 5' MIN. (1.6m) 10' MAX. (3.1m) 6' MIN. (1.9m) 12' MAX. (3.6m) V + H + H = 30’ MAX. (9.3 m) Ratio V to H + H = 1:2 H = 20' MAX.
  • Page 14 VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 3' MINIMUM (914 mm) 6' MAXIMUM (1.9 m) 4' MINIMUM (1.2 m) 8' MAXIMUM (2.4 m) 5' MINIMUM (1.6 m) 10' MAXIMUM (3.1 m) RATIO V TO H = 1:2 V + V + H + H = 30’...
  • Page 15: Installing Vent Components

    B. Installing Vent Components STARTING STARTING COLLAR COLLAR STOVE STOVE SEALANT SEALANT BEAD BEAD FIRST FIRST 3/8" (9.5 mm) 3/8" (9.5 mm) VENT VENT COMPONENT COMPONENT 3/8 INCH (9.5 mm) 1 INCH (25.4 mm)
  • Page 17 NOTE Model DVK-01TRD does not need an exterior firestop on an exterior combustible wall.
  • Page 19 JOIST CEILING NAILS (4 REQUIRED) CEILING FIRESTOP...
  • Page 20: C.vent Termination

    NAILS (4 REQUIRED) RAFTER CEILING CEILING FIRESTOP C. Vent Termination...
  • Page 21 (184mm)
  • Page 22 openable fixed closed J or K =VENT TERMINAL 1 2 3 1 2 3 =AREA WHERE TERMINAL IS NOT PERMITTED 1 2 3 =AIR SUPPLY INLET 1 2 3 = 12" clearances above grade, veranda, porch, deck or balcony = 12" clearances to window or door that may be opened = 9"...
  • Page 23 NOTE This also pertains to vertical vent systems installed on the outside of the building.
  • Page 24 TERMINATION (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING.
  • Page 25: Step 4 Positioning, Leveling, And Securing The Fireplace

    Step 4 Positioning, Leveling, and Securing the Fireplace Step 5 The Gas Control Systems Direct Spark Ignition (DSI).
  • Page 26: Step 6 The Gas Supply Line

    Step 6 The Gas Supply Line...
  • Page 27: Step 7 Gas Pressure Requirements

    USE A WRENCH ON SHUT-OFF VALVE WHEN TIGHTENING GAS LINE. Step 7 Gas Pressure Requirements...
  • Page 28: Step 8 Wiring The Fireplace

    Step 8 Wiring the Fireplace DISCONNECT REMOTE CONTROLS IF YOU ARE ABSENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION. For Direct Spark Ignition (DSI) Wiring CAUTION ANY REMOTE SWITCHING DEVICE USED FOR SETTING THE BURNER “HI” OR “LOW” MUST BE CONNECTED TO THE CORRECT PIGTAIL WIRES.
  • Page 29: Speed Control

    FAN WIRING DIAGRAM NOTE: IF ANY OF THE ORIGINAL WIRE NOTE: IF ANY OF THE ORIGINAL WIRE VARIABLE SPEED CONTROL AS SUPPLIED WITH THE APPLIANCE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 DEGREE C REPLACED WITH TYPE 105 DEGREE C RATED WIRE.
  • Page 30: Step 9 Finishing

    Step 9 Finishing NOTE: ALL DIMENSIONS SHOWN IN INCHES.
  • Page 31: Step 10 Installing Trim, Logs And Ember Material

    CAUTION IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND.
  • Page 33 CAUTION HAND TIGHTEN THE WING NUTS, BUT BE CAREFUL NOT TO OVERTIGHTEN. CAUTION IT IS STRONGLY RECOMMENDED THAT TRIM DOORS WITH OPTIONAL MESH SCREENS BE INSTALLED ON PROPANE MODELS.
  • Page 34: Step 11 Before Lighting The Fireplace

    Step 11 Before Lighting the Fireplace Installers Guide Step 12 Lighting the Fireplace After the Installation...
  • Page 35: Section 4: Maintenance And Servicing

    Fireplace Maintenance IMPORTANT TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE. Maintaining Type of Servicing Fireplace Fireplace Maintenance Task To Maintenance Frequency Be Completed Your Fireplace Replacing Once annually, Qualified Brush away loose ember material near Old Ember during the Service the burner.
  • Page 36 MAKE SURE THE FLAMES ARE STEADY - NOT LIFTING OR FLOATING. DSI IGNITION NOTE: FLAMES TOO CLOSE TO THE CERAMIC INSULATORS CAN CAUSE NUISANCE LOCKOUTS AND ELECTRODE FAILURE.