  • Page 1 Day Light Displays Screen Assemby Blocks 3x3 (R9850010) 4x3 (R9850020) 4x4 (R9850030) INSTALLATION MANUAL DAY LIGHT DISPLAY SYSTEMS...
  • Page 2 Trademarks are the rights of their respective owners All rights reserved Produced by BARCO NV, 19/06/2001 BARCO n.v./Daylight Display Systems Noordlaan 5 B-8520 Kuurne Belgium Tel : +32/56/368828 Fax : +32/56/368824 e-mail: sales.bps@barco.com Visit Barco on the web: http://www.barco.com Printed in Belgium...
  • Page 3 DAY LIGHT DISPLAY SYSTEMS Day Light Displays Screen Assemby Blocks 3x3 (R9850010) 4x3 (R9850020) 4x4 (R9850030) INSTALLATION MANUAL Date: 19/06/2001 Rev: 03 Art. No: R5976076...
  • Page 5: Table Of Contents

    Contents Order Numbers ............6 Exploded Image1 ................21 Image 2 Right side Springs ............... 22 Ordering spare/ replacement parts ............. 6 Exploded Image 2 ................22 Safety Guide Lines ..........7 Image 3 Bottom side removed ............23 Exploded Image 3 ................24 Safety guide lines ..................
  • Page 6: Order Numbers

    Order Numbers Ordering spare/ replacement parts R9828832 ..DIGITIZER ............... R9850290 ..DLITE FRONT ACCESS ........P14 R9850420 ..DIGITIZER ......... MIXER+LVDS R9850300 ..DLITE FRONT ACCESS ........P19 R9850080 ..DIGITIZER ........19"IP54 CASE R9850310 ..DLITE FRONT ACCESS ........P28 R9850361 ..
  • Page 7: Safety Guide Lines

    Structural & Mounting Components should be kept dry, clean, lubricated (only if recommended), coated properly, and otherwise maintained in a manner consistent with part design. BARCO products must be used in a manner consistent with their design and inspected on a routine basis for security, wear, deformation, corrosion and any other circumstances that may affect the load handling capability of the part.
  • Page 8: Safety Notice

    The power cords delivered with this system have special properties for safety. They are not user serviceable. If the power cords are damaged, replace only with new ones. Never try to repair a power cord. BARCO ——————————————————— 8 —————————— Daylight Display Systems...
  • Page 9: Additional Safety Notice

    • Use only with systems or peripherals specified by the manufacturer, or sold with the apparatus. Use caution during lifting/moving or transporting to avoid damage by possible tipping. BARCO ——————————————————— 9 —————————— Daylight Display Systems...
  • Page 10: System Overview

    Assemble displays on the ground and then raise to their desired position, depending on the circumstances and facilities available. Assembly displays are only to be used in conjunction with BARCO DLite Modules. Support Screen supporting/securing structures are not described herein, as these will vary from...
  • Page 11: Image 1 System Block Diagram

    Wall securing or supporting structures are not included. Always assemble a wall flat on the ground and then raise to its vertical position, dependent on the circumstances and facilities available. Image 2 Assembly on floor BARCO ——————————————————— 11 —————————— Daylight Display Systems...
  • Page 12: Tile Specification

    71.5 kg 71.5 kg 71.5 kg 71.5 kg Image 1 Front Three front access tools exist for removing tiles via the front of the Display (7mm/ Access Tools 10mm/28mm). 10mm not shown. 28mm BARCO ——————————————————— 12 —————————— Daylight Display Systems...
  • Page 13: Cabling & Caliber

    Cabling & Caliber What has to be done Necessary Tools Cables Part Detail/Article. no. Length Image Power Cables Power Source Cables emanate from the Power Box(s) (R9850050). Power Linking cables connect from tile to tile. Image 1 Power Source cable...
  • Page 14: Image 2 Power & Data Linking Cables

    Cabling & Caliber (Continued) Image 2 Power & Data linking cables Image 3 Safety Cable Image 4 Caliber tool...
  • Page 15: Example Installation

    Example Installation What has to be done Preparation Image 1 Example Assembly Block Assembly Block ï„ òƒ ò‚ ï Assembly Block Assembly Block...
  • Page 16: Assembly Preparation

    Assembly Preparation What has to be done connections of the assemblies, ensure only the recommended variants are used, to comply with safety guidelines. Necessary Tools General Joint/ Connections Example Example Image 1 Hammer Bolt joint Aluminum Profile Hammer Bolt Aluminum Corner...
  • Page 17: Image 2 Gap Between Profiles

    Assembly Preparation (Continued) Image 2 gap between profiles û ü Image 3 sides of profiles û ü û ü Image 4 angle between profiles 90º...
  • Page 18: Assembly Connection

    Assembly Connection What has to be done Necessary Tools Disconnecting Left Sides only Connecting Side to Side Example...
  • Page 19: Disconnecting Bottom Side

    Assembly Connection (Continued) Disconnecting procedure Bottom Side only Connecting Top to Bottom Example Example...
  • Page 20: Connecting Left & Top

    Assembly Connection (Continued) Connecting Left Connecting other Assembly-connections (like Assembly 2-2) & Top Example...
  • Page 21: Image 1 Left Side Removed

    Image 1 Left side removed Exploded Image1...
  • Page 22: Image 2 Right Side Springs

    Assembly Connection (Continued) Image 2 Right side Springs Exploded Image 2...
  • Page 23: Image 3 Bottom Side Removed

    Assembly Connection (Continued) Image 3 Bottom side removed...
  • Page 24: Exploded Image 3

    Assembly Connection (Continued) Exploded Image 3...
  • Page 25: Image 4 Left & Bottom Side Removed

    Assembly Connection (Continued) Image 4 Left & bottom side removed...
  • Page 26: Exploded Image 4

    Assembly Connection (Continued) Exploded Image 4...
  • Page 27: Tile Mounting

    Tile Mounting What has to be done Necessary Tools Mounting a Tile Image1 Tile attachments IMPORTANT all plug holder clamps must be locked firmly...
  • Page 28: Image 2 Tile Mounting

    Tile Mounting (Continued) Image 2 Tile Mounting Exploded Views 2 Tile Mounting Points...
  • Page 29: Image 3 Safety Cable

    Tile Mounting (Continued) Image 3 Safety cable...
  • Page 30: Tile Inter-Connection Cabling

    Tile Inter-Connection Cabling What has to be done Necessary Tools Tile Cabling Image 1 Tile rear Power OUT Data OUT Connection Module IMPORTANT all plug holder clamps must be locked firmly Power IN Data IN...
  • Page 31: Power Connections

    Power Connections What has to be done Necessary Tools Power Connections For safety reasons, it is not advised to use any other parts than those recommended. Image 1 Power...
  • Page 32: Image 2 Power Linking

    Power Connections (Continued) Image 2 Power linking ADHERE TO SAFETY GUIDE LINES daisy chained to maximum 6 tiles per branch POWER BOX COMPLETE DISPLAY NOT SHOWN ONLY THE PRINCIPLE IS DEMONSTRATED...
  • Page 33: Data Connections

    Data Connections What has to be done Necessary Tools Data Connections For safety reasons, it is not advised to use any other parts than those recommended.
  • Page 34: Image 1 Data Linking

    Data Connections (Continued) Image 1 Data linking ADHERE TO SAFETY GUIDE LINES FIRST TILE MAY LAST TILE WILL BE IN ANY CORNER BE IN A CORNER daisy chained to all tiles TO DISPLAY DIGITIZER COMPLETE DISPLAY NOT SHOWN ONLY THE PRINCIPLE IS DEMONSTRATED...
  • Page 35: Wall Trim

    Wall Trim What has to be done Necessary Tools Trim Mounting Image 1 Trim around Wall...
  • Page 36: Tile Accessing

    Tile Accessing What has to be done Necessary Tools Back Access Front Access Hot Swap...
  • Page 37: Image 1 Back Access

    Tile Accessing (Continued) Image 1 Back Access ADHERE TO SAFETY GUIDE LINES Image 2 Front Access...
  • Page 38: Digitizer

    Digitizer What has to be done Necessary Tools Digitizer Connections Image 1 Front Digitizer Image 2 Back Digitizer...
  • Page 39: Complete System Setup

    Complete System SetUp What has to be done Necessary Tools Connections Image1 System connection. ADHERE TO SAFETY DISPLAY GUIDE LINES DATA IN TO DISPLAY POWER SOURCE CABLE OUTLETS Source POWER BOX Signals DIGITIZER RS232 IN MAX 12 POWER OUTPUTS PER BOX RS232 OUT CORNER TILE (START POINT FOR DATA CONNECTION.