Hose Rewind Made Easy With The De212 Wireless Deadman; Coding The Transmitter And The Receiver; Operational Requirements - Delta DE212 Installation And Operation Manual

Table of Contents

Advertisement

3.3.1 Hose rewind made easy with the DE212 wireless deadman

The DE212 system has an extra function. This can be used for additional functions, like hose
rewind. This function is implemented in the system so it can NOT be activated simultaneously
with the Deadman function, That means that when refuelling, the Hose rewind function is
de-activated and can not start the rewind of the fuelling hose and Nozzle.
Remote rewind makes the operation goes faster with better control and reduces the physical stress
of the operator and the hose and Nozzle. The operator walks back to the vehicle carrying the
Nozzle, see photo.

3.3.2 Coding the transmitter and the receiver

In order to make the receiver execute a function, the code in the handheld unit, the transmitter, must
be transmitted to the receiver and correspond with the code stored in the receiver.
The DE212 system has 65.536 different codes available. Each code and serial number of the unit is
logged by the producer and used only once.
The transmitter is hard-coded from the factory, while the receiver must be coded by the user before the
system goes into normal service.
Coding:
Press the yellow CODE button on the receiver front panel and keep it pressed simultaneously with the
red transmitter STOP button until the Green ON-LED flashes three times, then release both buttons.
The three flashes indicates that the code is stored. The system is now ready to operate. The old code
is erased and the new code is stored in the receiver even if the power is turned off.
Erasing the code:
The stored code in the receiver is erased by pressing first the Deadman button on the transmitter then
the CODE-button in the receiver, after some seconds, the green ON flashes 5 times, and the code is
erased. To maintain normal operation again, the receiver must be re-coded.

3.3.3 Operational requirements

Please observe the following. This is mandatory to maintain a safe operation.