2.10 Changing the function of the receiver unit by DIP SW3.
The function of the receiver unit can be changed according to operational requirements.
The following can be changed:
•
SW3-1: Timed or no timed Deadman. ON is activated.
With timer OFF, the deadman function will work as a normal ON-OFF switch with no time delay.
•
SW3-2: Simultaneous or no simultaneous operation of the extra function at the handheld
transmitter.
•
SW3-3: External override, enabled or disabled
•
-4: Differential Pressure Switch/ DP input at P3-2
SW3
•
-5: Wired Deadman input, P3-4. ON/OFF Deadman or Faisafe Delta Deadman
SW3
Default settings are shown
ON
To store the DIP SW3 settings in the receiver:
1.
Set the function switch, SW3 to the desired positions.
2.
Take out the fuse, F2 or switch OFF the power input.
3.
Press the yellow CODE-button on the receiver front and keep it pressed. Replace the fuse, or
switch ON the power of the receiver. Watch the green ON LED, keep the CODE-button pressed
until the green ON LED turns on. Normally the time for reading the new settings of the SW3,
takes about 3 secs.
When the ON is green, it indicates that the new settings of SW3 are successfully stored, and
the receiver is ready to operate.
2.11 DP-sensor connection
The receiver is prepared for connection of a DP-sensor, for Differential Pressure
protection. This sensor can be of different types.
For further information, see document 03073 or contact Delta RC,
D
RC AS
ELTA
.
Standard factory settings of
SW3
Function
1
Deadman timer max 2min.
In OFF, instant operation, no
delays
2
Function 2:
OFF=Can not work
simultaneous with the
Deadman function
ON= Can work simultaneous
with the Deadman function
3
Deadman external override
4
DP sensor input
5
Wired deadman input
OFF=ON/OFF deadman switch
ON= Delta Failsafe wired
deadman
6
TBD
7
TBD
8
TBD
.
enabled or disabled
SW3
switches:
Comments
ON=Active Default
OFF= No timer
OFF=Default
For Hose reel operation.
ON: for pump speed
control
OFF= Default, not active
OFF= Default, not active
ON= DP sensor is read
OFF=Default
Optional
OFF= Default
OFF= Default
OFF= Default