Delta DE212 Installation And Operation Manual page 10

Table of Contents

Advertisement

Connector
P1 in
receiver
1
Output; buzzer or flash-light timer warning
2
Output; Timer warning
3
Output; Extra function, for
hose reel or pump speed control
4
5
Ouput; Normally ON= high output
Goes low when STOP at transmitter is active
6
Output; High output when transmitter is
7
Minus-pole for input voltage
8
Plus-pole for input voltage
9
10
Input signal; DP Reset / Override
Note: High outputs are 12 or 24V when activated, same as the receiver supplied voltage.
Receiver connections, connector P3
Functions installed with receiver software program: 02907
Conn.
Functional description
P3
External override
1
The Deadman function is active as long as this input
is low, connected to GND
2
DP sensor input
External STOP.
3
Input signal. Stops all functions in the receiver when
connected to GND
Wired Deadman input, ON/OFF deadman or
4
Delta Failsafe
GND, ground or common terminal.
5
Same as P1-7 and P2-3
NOTES:
The receiver works with supply voltage 11 to 35 V DC. All outputs give supply voltage out when
activated.
NOTE: Input voltage above 35V, will shut down the receiver.
The timer warning output operates as follows: when the Deadman function is activated, the time
warning output also go active, supplying 12/24V out. When 30 seconds are left of the 2 min. time
period, the standard period, the output change from a steady output, to an off/on signal during the last
30 seconds of the time period. The output is intended for connection to an indicating lamp, visible for
the operator. The on/off flashing lamp is intended to warn the operator to restart the time period.
D
RC AS
ELTA
Function
Deadman output
STOP
stowed for charging
Output, F7
:
Comments
Select SW3, see section 2.9
Output is high during the last 30 sec of the timer
period. To give an extra warning by sound or light.
SW3-1 Deadman timer
Active high when deadman output is active. When
30 sec. remains of the max 2min. period, the output
goes OFF/ON with 1sec. intervals until the period is
restarted or it times out and stops the fuelling.
SW3-2: Extra function.
Simultaneous or no simultaneous operation with the
Deadman function.
ON = Simultaneous operation
Active high when deadman is activated.
Timer limit without restarting is 120sec/2min.
Output for remote emergency stop of External units
Output for interlock of vehicle operation, to force
operator to stow the transmitter for charging.
GND, normally connected to chassis.
Voltage range: 11-27VDC
For future expansions.
Low input, less than 0,3V resets DP and override the
fuelling stop.
Functional settings
SW3-3 : External override
ON= Ext. override enabled.
OFF=Ext. override disabled
SW3-4, see section 2.10
This function is always enabled
SW3-5. Optional. Contact
distributor or Producer.
Document no: 03039
Page 9 of 33