PerkinElmer QuickSTAR Horizon Operation Manual
PerkinElmer QuickSTAR Horizon Operation Manual

PerkinElmer QuickSTAR Horizon Operation Manual

Strip reader

Advertisement

Quick Links

TM
OPERATIONS MANUAL
Catalog #FOOD-6006-01
MN50-6006-01 • Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for PerkinElmer QuickSTAR Horizon

  • Page 1 OPERATIONS MANUAL Catalog #FOOD-6006-01 MN50-6006-01 • Rev. A...
  • Page 2: Table Of Contents

    NOTICES Except as specifically set forth in its terms and conditions of sale, PerkinElmer, Inc. and its subsidiaries (“PerkinElmer”), make no warranty of any kind, either express or implied, with regard to this document or the use of the product, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 3: Product Overview

    Strip Reader is a hand-held instrument designed to quickly read ™ ™ and analyze lateral flow and dry chemistry test strips from PerkinElmer . The unit provides qualitative and fully quantitative test results in less than ten seconds . Key Features •...
  • Page 4: General Features And Overview

    GENERAL FEATURES AND OVERVIEW Items Provided 1 . QuickSTAR Horizon Strip Reader ™ ™ 2 . USB Data Connection Cable 3 . Power Supply Adapter 4 . QuickSTAR Horizon Cartridge Adapters #1 and #2 ™ ™ 5 . Data Manager Software Suite can be downloaded from the following website: bit .ly/QuickSTARHorizon Charging the Unit To charge your QuickSTAR...
  • Page 5: Theory Of Operation

    POWER The power button should be used to power down the device, and if there is a need for a hard shutdown in the event the unit freezes and becomes unresponsive . Alternately, use the Total Power Down method by following on-screen Menu Power Power Off...
  • Page 6: Running A Test

    RUNNING A TEST To run a test on the reader, turn the reader on, select the User, or add a new one . The reader will then display the Main Menu with the time and two fields: Category, and Test Name .
  • Page 7: Data Manager Software

    2 . Double click on DataManager .exe 3 . Follow on-screen installation instruction to choose the installation folder and install the data manager 4 . The program shortcut will be named PerkinElmer Data Manager Importing Data Using Data Manager Software Connect the QuickSTAR Horizon unit to your computer using the USB cord plugged into ™...
  • Page 8: User Control Menu

    USER CONTROL MENU Main Menu When the QuickSTAR Horizon strip reader is powered on, the User selection window will ™ ™ appear . Once the User is selected, the Main Menu will be displayed . The user may return to the Main Menu using the button below the screen, or whenever the appears at the...
  • Page 9: Touch-Screen Menu

    Touch-screen menu OPTIONS Selecting on the Main page will bring up a menu screen where the user may view results, edit the user list, update the software and reset or power off the QuickSTAR Horizon reader . EDITING THE USER LIST From the Screen, select User...
  • Page 10: Resetting And Rebooting

    RESETTING AND REBOOTING Soft Reboot Of The Reader In rare cases when the reader becomes slow or unresponsive, a reboot may be necessary 1 . Select the Menu, choose Power . Alternately, press the Power button below the touch screen . 2 .
  • Page 11: Notification Icons

    NOTIFICATION ICONS On the bottom of the display there are two Notification Icons . Connection Status Connect the mini-USB end of the cable to the left USB port of the reader, and the USB end to a USB port of a computer . Click the then the USB Connection icon on the reader...
  • Page 12 Austin, TX 78744 USA P: (888) 208-2246 or (+1) 512-707-8993 www.biooscientific.com For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright © 2019, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other ®...