- EN - INTRODUCTION This manual is an integral part of the dryer you bought, and must remain with the machine even if this will be resold. - EN - It is highly recommended that the qualified*personnel for installation maintenance and/or control will fully comply with the contents of this manual and the prevention and safety rules in force in the country where the system will be used.
2. INSTALLATION Correction by the Company of nonconformities whether patent or latent, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of the Company for such nonconformities whether based on contract, warranty 2.1 ACCEPTANCE, UNPACKING AND HANDLING negligence, indemnity, strict liability or otherwise with respect to or arising out of such Equipment.
Page 5
NOTE: Changes entered for timing values will be effective only after exiting the programming, while changes to other variables will be immediately effective. DISPLAY VISUALIZATION AND SIGNALLING LEDS ( D12IN-A ÷ D480IN-A) Please remember that eventual changes to the configuration parameters of the machine could negatively affect its efficiency.
4.2 TROUBLESHOOTING NOTE: FOLLOWING BEHAVIORS ARE NORMAL CHARACTERISTIC OF OPERATION AND NOT TROUBLES • Variable speed of the fan. (Mod D12IN-A ÷ D480IN-A) • Display of message ESA and ES2 in case of operation without load or low load. •...
Page 7
TROUBLE DISPLAY POSSIBLE CAUSE REMEDY TROUBLE DISPLAY POSSIBLE CAUSE REMEDY Check the probe; if the trouble persists, replace it. No power in the line. Restore the power in the line. Control panel Check the electronic control board; if the trouble persists, Problems with cabling.
Page 8
4.3 DECOMMISSIONING Pic.5 In case of necessity, decommission the machine and the relevant packaging in compliance Option: No loss condensate drain (Zero Drain) with the rules locally in force. Zero Drain is the new electronic drain discharger applicable to any Pay particular attention to the refrigerant, as it contains part of the refrigerating compressor compressed air systems.
ATTACHMENTS TO THIS MANUAL Legend High pressure Switch Fan Motor Refrigerant compressor Drain solenoid valve coil Electronic Controller Air filter 5 micron Air filter 1 micron Air filter 0.01 micron Filter dryer Air filter 10 micron F1-F2 Fuses Evaporator Fan contactor switch Contactor switch Moisture indicator Grid...
Page 11
Cod. 713.0034.03.00 – Rev. 00 Models D780IN-A to D950IN-A Condensate drain Air inlet Air outlet Refrigerant line Compressed air line Condensate drain line Equalization line 15 - 35 Cod. 710.0138.45.00 Rev04 – 02.2019...
AIR FLOW RATE Air flow rate POW SUPPLY Power supply Nominal power Nominal consumption Max kW Full load consumption Nominal Current Full load current Locked rotor current CONN Air connections AIR T Air inlet temperature AIR T MAX Max, air inlet temperature AMB T Ambient temperature AMB T MAX...