Ingersoll-Rand RS45-75 400/3/50 Operator's Manual

Ingersoll-Rand RS45-75 400/3/50 Operator's Manual

Hide thumbs Also See for RS45-75 400/3/50:

Advertisement

DIRECT EXPANSION COMPRESSED AIR DRYERS
- EN -
Operators Manual
RS45-75
Cod. 710.0048.24.02 Rev00 – 10.2017

Advertisement

Table of Contents
loading

Summary of Contents for Ingersoll-Rand RS45-75 400/3/50

  • Page 1 DIRECT EXPANSION COMPRESSED AIR DRYERS - EN - Operators Manual RS45-75 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 2 1 - 21...
  • Page 3: Table Of Contents

    - EN - CONTENTS 1. GENERAL INFORMATION 1.1 Functional description 1.2 Safe use of the dryer 2. SAFETY INFORMATION 2.1 General safety instruction 2.2 Equipment nameplate values 2.3 Information about remaining risks of the equipment 3. INSTALLATION 3.1 Acceptance and transportation 3.2 Installation site 3.3 Installation 4.
  • Page 4 - EN - INTRODUCTION This manual is an integral part of the dryer you bought, and must remain with the machine even if this will be resold. It is highly recommended that the qualified*personnel for installation maintenance and/or control will fully comply with the contents of this manual and the prevention and safety rules in force in the country where the system will be used.
  • Page 5: General Information

    THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HERBY DISCLAIMED. Correction by the Company of nonconformities whether patent or latent, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of the Company for such nonconformities whether based on contract, warranty negligence, indemnity, strict liability or otherwise with respect to or arising out of such Equipment.
  • Page 6: Safety Information

    2. SAFETY INFORMATION 2.1 GENERAL SAFETY INSTRUCTION SAFETY INFORMATION This dryer has been designed and manufactured in accordance with the European safety directive 2006/42/EC Machine Directive 2014/30/EU Electromagnetical compatibility Directive 2014/68/EU PED Directive According to PED Directive, this plant is supplied with safety devices on the frigorific circuit, calibrated according to the under mentioned specifications.
  • Page 7: Acceptance And Transportation

    Such devices will have to be carried out according to the applicable National Norms and to the limits mentioned in this Manual. Ozone layer deterioration: The adoption of HFC freon reduce to the minimum ozone layer deterioration and greenhouse effect. 3.
  • Page 8: Installation

    3.3 INSTALLATION Before attempting any installation operation, make sure that No parts of the air system are under pressure. No parts of the system are electrically powered. Tubing to be connected to the dryer are free of impurities. All interconnecting piping has been tightened. After having verified the points listed above, you can proceed to the installation of the machine.
  • Page 9: Maintenance

    5. MAINTENANCE, TROUBLESHOOTING AND DECOMMISSIONING 5.1 MAINTENANCE Before attempting any maintenance operation, make sure that: 1. No parts of the system are under pressure. 2. No parts of the system are electrically powered. WEEKLY OR EVERY 40 HOURS OF OPERATION Verify the temperature on the control panel display is acceptable.
  • Page 10: Dismantling

    The condenser is dirty. Clean the condenser. Fan pressure switch defective or burned out (if Turn off the dryer and call your local Ingersoll Rand distributor. present). High pressure switch defective or burned out (if Turn off the dryer and call your local Ingersoll Rand distributor. present).
  • Page 11: Attachments To This Manual

    ATTACHMENTS TO THIS MANUAL Legend: Pos. - GB - DESCRIPTION Electronic Controller Drain solenoid valve coil Refrigerant compressor Fan Motor High pressure Switch Fan pressure Switch Compressor circuit breaker Fan circuit breaker Main power switch Plug Transformer Solenoid drain Valve Compressor box Cables Condenser...
  • Page 12: A) Refrigerant Circuit

    A) REFRIGERANT CIRCUIT Cod. 713.0058.01.00 – Rev. 01 Condensate drain Refrigerant line Air inlet Compressed air line Air outlet Condensate drain line Equalization line 10 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 13: B) Electric Circuit Diagram

    B) WIRING DIAGRAM - RS45-75 400/3/50 Cod. 714.0186.01.00 – Rev. 0E Power wiring diagram Control circuit diagram 11 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 14 Terminal blocks Component layout 12 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 15 - RS45-75 460/3/60 Cod. 714.0174.01.00 – Rev. 1C Power wiring diagram Control circuit diagram 13 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 16 Terminal blocks Component layout 14 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 17 – RS45-75 230/3/60 Cod. 714.0174.02.00 – Rev. 1B Power wiring diagram Control circuit diagram 15 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 18 Terminal blocks Component layout 16 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 19 – RS45-75 380/3/60 Cod. 714.0174.03.00 – Rev. 0C Power wiring diagram Control circuit diagram 17 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 20 Terminal blocks Component layout 18 - 34 Cod. 710.0048.24.02 Rev00 – 10.2017...
  • Page 21: C) Technical Data Sheet

    C) DATA SHEET MODEL RS45-75 AIR FLOW RATE* 400/3/50 460/3/60 230/3/60 380/3/60 POW SUPPLY VOLT/PH/HZ 2.31 3.15 3.15 3.15 Max kW 3.60 4.71 4.71 4.71 5.62 5.70 10.72 6.11 COMPRESSOR 7.05 7.33 13.78 7.85 0.46 0.72 0.70 0.70 FAN MOTOR 1.02 1.17 2.15...
  • Page 22: D) Dryer Dimensions

    Legend: Pos. - GB - DESCRIPTION Pos. - GB - DESCRIPTION AIR FLOW AMB T Air flow rate Ambient temperature RATE Min-Max. ambient POW SUPPLY AMB T MIN-MAX Power supply temperature AIR W PRESS Nominal power Air working pressure Nominal consumption AIR PRESS MAX Max.
  • Page 23: E) Spare Part List

    E) SPARE PARTS LIST RS45-75 Model 400/3/50 460/3/60 380/3/60 230/3/60 Pos. Element Temperature probe 23807951 23807951 23807951 23807951 Refrigerant compressor 47573720 47573720 47587274 47587273 Fan Motor Fan blade 23763725 23763725 23763725 23763725 Grid High pressure switch 47614661 47614661 47614661 47614661 Fan pressure switch 18301622 18301622...

This manual is also suitable for:

Rs45-75 460/3/60Rs45-75 380/3/60Rs45-75 230/3/60

Table of Contents