Expansion Modules
MODEL
Flow Rate
(@16mJ/cm
Flow Rate
(@30mJ/cm
Flow Rate
(@40mJ/cm
Filter Housing - 1
Filter Housing - 2
Port Size
Electrical
Plug Type
Lamp Power (Watts)
Power (Watts)
Replacement Lamp
Replacement Sleeve
Chamber Dimensions
Chamber Material
Controller Dimensions
Operating Pressure
Operating Water Temperature
UV Monitor
Solenoid Output
Dry Contacts
4-20mA Output
Lamp Change Reminder
(audible & visual)
Lamp Out Indicator
(audible & visual)
Microlene EQUIPMENT SPECIFICATIONS
)
2
)
2
)
2
Polished 316L Stainless Steel, A249 Pressure Rated Tubing
YES (optional solenoid module sold separately)
RACK-MOUNT UV SYSTEMS
MCS
30.1 USgpm
114 lpm
6.84 m
15.0 USgpm
56.8 lpm
3.4 m
12.0 USgpm
45.4 lpm
2.7 m
20 micron sediment
20PP20J
1 micron sediment
1PS20J
1"FNPT (filter side) / 1" MNPT (UV side)
90-265V/50-60Hz
Australian/New Zealand: AS/NZ 3112
45 (high-output lamp)
57 (48 @ 230V)
MC-HOLP
MC-HOSL
8.9 x 50.8 cm
(3.5 x 20")
21.8 x 10.7 x 8.9 cm (8.6 x 4.2 x 3.5")
827kPa (120PSI)
2-40° C (36-104° F)
not available
not available
not available
YES
YES
21
MCSX
/hr
3
/hr
3
/hr
3
OPTIONAL
(optional UV module sold separately)
YES
(remote alarm module sold separately)
YES
(remote alarm module sold separately)