Bunn ITB/ITCB Programming Manual page 31

Bunn coffeemaker user manual
Table of Contents

Advertisement

TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start
PROBABLE CAUSE
1. No water
2. No power or incorrect voltage to
the brewer
3. ON/OFF switch
4. Brew switch
5. Brew valve
6. Control Board
Page 31
REMEDY
Check plumbing and shut-off
valves
Check for voltage across the termi-
nals at the terminal block.
Test the ON/OFF switch. Refer
to the test switch procedures on
page 50.
Test the BREW switch. Refer to the
test switch procedures on page
50.
Test the brew valve. Refer to the test
outputs procedures on page 48.
Substitute a control board known
to be in good working order.
41581.2 091609

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Infusion itb/itcbInfusion icb/twin

Table of Contents