1.5
C
HANGING THE FUNCTION OF THE RECEIVER UNIT BY
From May 2007, a new software, item nr 02017, was introduced in the receiver unit.
With this software, the function of the receiver unit can be changed according to operational
requirements.
The following can be changed:
**SW2-1: Timed or no timed deadman. ON is activated.
** SW2-2: Simultaneous or not
when the deadman is activated.
** SW2-3: External override, active or off.
Standard factory setting of SW2 switches:
ON
OFF
1
2
__
3
4
1.
Set the function switch, SW2 to the desired position
2.
Take out the fuse, F1.
3.
Press the receiver front button CODE while replacing the fuse. Press the CODE button for about 3
seconds, then the function is changed according to settings.
SW2 Switch for function selection
NOTE: The connector P3 for external override and STOP is normally not installed
This functions must be specified when ordering.
D
RC AS
ELTA
simultaneous operation of the extra function, connection P1-3.
1. Deadman timer enabled, 2 min timer (Default „ON")
2. Not simultaneous operation of extra function (Default „OFF")
3. Deadman override input disabled (Default "OFF")
4. Not in use (Default "OFF")
User and Installation Manual, DE212-2S DSD
SW2.