3. R
EPLACING THE BATTERY
Note:
The battery module 02465 has an integrated fuse. This fuse will brake and disconnect the battery
power from the connector if overloaded. The inside fuse can not be replaced, the complete battery module
must be replaced.
The battery module 02465 and all replaceable parts of the transmitter, must be original parts delivered by
Delta RCS AS. Otherwise the Ex certifications are lost, and the customer has to take all responsibilities.
The operator is allowed to change the battery module and nothing else.
From December 2013, the battery module is changed, in accordance with the IECEx certification. The new
battery module for IECEx is: 02465.
The battery replacement operation must take place outside Ex-area.

When the battery module has to be changed, it has to be done as follows:

** Verify that battery module 02465 is replaced by 02465 and no other versions of the battery module. 
** Open the bottom end of the transmitter, by pressing the two lock-sections in.
** Pull the battery module gently out of the housing without jamming the O-ring.
** Disconnect the battery from connector marked "3" on the PCB, by lifting the connector up.
See section 5.3.2
** Put a thin layer of Vaseline on the new battery module O-ring
** Connect the new battery, and push the battery module back into the housing. Make sure that the
O-ring and connecting wires are not jammed during this operation.
** When the operation is finished, charge the battery for 3 hours, and test all functions.
See section 2.5