Technical Data - Delta DE212-2S GLOBAL DSD Operation And Installation Manual

Wireless deadman system
Table of Contents

Advertisement

6. T
D
ECHNICAL
This equipment complies with the following standards:
Europe/EU: ERC 70-03 EN 300-400. USA: FCC 15.249. Japan: STD-T66.
It is in accordance to EU's demands in order to label the equipment with CE.
Transmitters are IECEx approved, according to:
IECEx: IEC 60079-0 Ed.5 and IEC 60079-11 Ed. 5
IECEx certification: IECEx ZLM 13.0005X
General Specification
Frequency: 2,4 GHz
Modulation: GFSK
Coding:
Digital coding, 65.536 different pre-set codes from manufacturer.
Functions: Three functions, Deadman, STOP and one extra.
Temperature Range: Operational:
Storage:
-40 to +65º C. Charging: 0 to +50º C.
Shock Resistance:
Receiver
Antenna
External standard aerial, 14,5 cm long. With FME connector on receiver top.
Power Supply:
Power Consumption: Standby: 55mA.
During full charging
Outputs:
Semiconductor. 2A, each. 12/24 V DC output when active.
Deadman output.
Interlock, output when transmitter is in the charging station.
Timer warning signal.
Beeper warning output.
Normally closed output, opens when STOP is activated.
Transmitter charging Front panel charging station for transmitter, max current 50mA.
Connections:
Controls:
1 push-button CODE, for coding to the transmitter.
Indicators: Green light diode that indicates power on.
Yellow light diode that indicates recharging and in operation.
Housing:
ABS polycarbonate, class IP52.
Dimensions: L:160 mm, W: 80 mm, D: 60 mm.
Weight:
0.3 kg
D
RC AS
ELTA
ATA
-20 to +50º C. For lower temperature, contact producer.
1 m free-fall on concrete floor.
11 to 27 V DC. Voltage above 35VDC shuts down the receiver.
110mA.
Screw terminal on PCB connector.
User and Installation Manual, DE212-2S DSD
Page 21 of 24
Document 02481

Advertisement

Table of Contents
loading

This manual is also suitable for:

02910

Table of Contents