Receiver connections, connector P3:
Note that connector P3 is not installed unless programme 02046 and this functions are ordered.
Functions installed with receiver programme: 02046
Connector P3
Functional description
External override
The deadman function is active as long as this input is
1
low, connected to GND
Not in use, for future expansion.
2
External STOP.
3
Stops all functions in the receiver when connected to
GND
Not in use, for future expansion.
4
GND, ground or common terminal. Same as P1, term. 7
5
NOTES:
•
Input voltage is 11 to 35 V DC. All outputs give input voltage when activated.
•
NOTE: Input voltage above 35V, will shut down the receiver.
•
Note that the potential between the minus pole and ground, must not be greater than 50VDC/AC peak.
•
The timer warning output operates as follows: when the deadman function is activated, the time warning
output also go active, supplying 12/24V out. When 30 seconds are left of the 2 min. time period, the
standard period, the output change from a steady output, to an off/on signal during the last 30 seconds of the
time period. The output is intended for connection to a indicating lamp, visible for the operator. The on/off
flashing lamp is intended to warn the operator to restart the time period.
•
The timer beeper output is active only as long as the warning signal is flashing.
If external connection box is delivered, the connections are as follow:
Cable
Receiver
connector
marking
connection
YE-GN
6
6
5
5
4
4
3
3
2
2
1
1
7
7
8
8
D
RC AS
ELTA
Function
Not in use
Interlock
STOP
Deadman output
Extra function
Timer warning
Timer beeper
Minus-pol, spenning inn
Spenning inn, 12/24VDC
User and Installation Manual, DE212-2S DSD
SW2-3 : External
override
ON= external override
active. OFF=disabled
This function is always
enabled
Page 7 of 24
Document 02481