Installation sequence
Installation
(cont.)

Fitting the cylinder temperature sensor

Note
The cylinder temperature sensor is supplied in the con-
trol unit pack.
1.
2.
3.
4.
Fig.11

Connections on the heating water side

Any number of heating water buffer cylinders can be
connected up in series or in parallel. The connection
pipes and air vent valves must be provided on site.
!
Please note
The thermal insulation must not come into con-
tact with naked flames.
Exercise caution when welding and brazing.
Permissible temperature
Heating water flow
Permissible pressure
Operating pressure
Test pressure
14
Sensor well
If a thermometer sensor is already fitted inside the
sensor well, be careful not to kink the sensor lead.
Note
For connection locations, see page 5.
1. Connect all pipework with detachable fittings.
2. Install the flow line with a rise. Fit an air vent valve
at the highest point of the flow line.
3. Check all connections for leaks after filling the cylin-
der.
110 °C
3 bar (0.3 MPa)
4.8 bar (0.48 MPa)