Variable area flow meter with glass measuring tube

Advertisement

Limit Switches

The flowmeters can be equipped with a maximum of two limit switches.
The switching function of the limit switch can be designed as monostable or bistable.
Monostable function: Switching pulse as float passes through switching point,
Bistable function:
Example (bistable):
For switching performance and electrical data refer to section "Technical data".
Electrical connections:
Connection of limit switch - 2-wire NAMUR (standard):
1 Lower limit switch to terminal 1
2 Upper limit switch to terminal 2
The connection box includes an EMC filter unit.
DS10 Instruction manual 11/2021
independent of direction of movement.
Stable changeover as float passes through switching point.
Above limit: switching point "High"
Below limit: switching point "Low"