Download Print this page
Keysight N9068A Demo Manual
Keysight N9068A Demo Manual

Keysight N9068A Demo Manual

X-series measurement application

Advertisement

Quick Links

Keysight Technologies
N9068A & W9068A Phase Noise
X-Series Measurement Application
Demo Guide
This demonstration guide will guide you through some
typical usage scenarios for the Keysight Technologies, Inc.
X-Series signal analyzers with the N9068A/W9068A phase
noise measurement application. Each demonstration is given
a brief description of its function and the corresponding
measurement steps on the signal generator and/or signal
analyzer.

Advertisement

loading

Summary of Contents for Keysight N9068A

  • Page 1 X-Series Measurement Application Demo Guide This demonstration guide will guide you through some typical usage scenarios for the Keysight Technologies, Inc. X-Series signal analyzers with the N9068A/W9068A phase noise measurement application. Each demonstration is given a brief description of its function and the corresponding measurement steps on the signal generator and/or signal analyzer.
  • Page 2 – Option 503 or any other frequency option display. analyzer N9000A CXA Phase noise – Option 2FP – fixed perpetual license N9068A (PXA, MXA, EXA) measurement – Option 2TP – transportable perpetual W9068A (CXA) application license (not available for CXA)
  • Page 3: Getting Started

    Demonstrations Demonstration 1: Instructions Keystrokes On the MXG signal generator Getting started Preset the MXG [Preset] Set up the signal under test at 1 GHz The signal under test is simply a center frequency and –10 dBm output [FREQ] [1] {GHz}; [AMPLD] [-] [10] {dBm} continuous-wave (CW) RF signal from level the MXG.
  • Page 4: Log Plot Measurement

    Demonstration 2: Instructions Keystrokes On the X-Series in Phase Noise mode: Log plot measurement View log plot [Meas] {Log Plot} The log plot is the most-frequently Set the signal analyzer with a carrier fre- [FREQ Channel] {Carrie Freq} [1] used presentation of a DUT’s phase quency of 1 GHz and an amplitude reference {GHz};...
  • Page 5 Demonstration 3: Instructions Keystrokes On the X-Series Phase Noise mode: Integrated noise View Log plot [Meas] {Log Plot} measurement Set the signal analyzer with a carrier [FREQ Channel] {Carrie Freq} [1] {GHz}; Depending upon applications, other frequency of 1 GHz and an amplitude [AMPTD Y Scale] {Ref Value} [0] {dBm} aspects of the phase noise may better reference level of 0 dBm...
  • Page 6 Demonstration 4: Instructions Keystrokes On the X-Series signal analyzer: Spot frequency measurement Start Spot frequency [Meas] {Power Stat CCDF} Spot frequency measurement inves- Set the signal analyzer with a carrier [Trace/Detector] {Store Ref Trace} tigates the phase noise behavior at a frequency of 1 GHz specific offset frequency by providing Set the spot offset frequency to 10 kHz...
  • Page 7 The DANL mea- following DANL subtraction {Trace 2} {To Trace} {Trace 3} {Copy Now} surement provided by the N9068A/ [Meas Setup] {More 1 of 2} {Cancellation} W9068A measures and references the {Cancellation On} {Ref Trace} {Trace 3};...
  • Page 8: Additional Resources

    08 | Keysight | N9068A & W9068A Phase Noise X-Series Measurement Application – Demo Guide For more information on Keysight myKeysight Technologies’ products, applications or www.keysight.com/find/mykeysight services, please contact your local Keysight A personalized view into the information most relevant to you.