Ecomiser SU-01 Manual page 16

Hide thumbs Also See for SU-01:
Table of Contents

Advertisement

7. ERROR MESSAGE
1)
ER1: Wash temperature sensor If OPEN or SHORT, temperature is above 100ºC
(230ºF)
2)
ER2: Upper rinse tank temperature sensor if OPEN or SHORT, temperature is above
110ºC (230ºF)
3)
Er3: Lower rinse tank temperature sensor if OPEN OR SHORT, temperature is above
110ºC (230º)
4)
EF1: Water supply ERROR, problem with rinse tank FLOAT SWITCH, displays if there is
no signal from the FLOAT SWITCH after 15 minutes of water supply.
5)
EF2: Water supply ERROR, problem with rinse tank FLOAT SWITCH, if there is no water
supply to the tank for more than 40 minutes.
6)
Ed1: Upper OVER FLOAT SWITCH ERROR, if upper OVER FLOAT SWITCH is turned
on.
7)
Miscellaneous:
7-1) if there is any type of ERROR, machine will completely stop.
7-2 ERROR buzzer will sound 5 consecutive times.
7-3) POWER button or START/STOP button will clear the ERROR status, but unless
8. SETTING DATA
1)
When the machine is turned off, all pre-set data will be saved.
2)
Pre-set data consists of wash time / detergent time / wait time / rinse time / rinse agent
time, temperature setting, buzzer sound, temperature unit, and model number.
Ecomiser SU-01 / SU-02 Manual – Rev. 06
the ERROR is fixed, ERROR message will continue to display
EF1