Ecomiser SU-01 Manual page 10

Hide thumbs Also See for SU-01:
Table of Contents

Advertisement

Figure 1-2 Fresh water connection
NOTE
In some cases, local codes dictate that water supply connections be made only by a certified
professional.
- Check that iron or other metal particles cannot contaminate the fresh water supplied to the machine.
- Check that the incoming water pressure is within the acceptable range for the machine (10 - 40 psi,
0.7 - 2.8 bars). It may be necessary to reduce the pressure.
- Check the incoming water temperature. Colder water will result in a longer preheat time (during
initial startup) and may extend the cycle time to allow the final rinse water to heat to minimum
180°F/82°C.
- Check the incoming water hardness. The Ecomiser SU-01 / SU-02 Models require a hardness of 4
grains per U.S. gallon or less. If over 4 grains the water should be treated.
- When connecting the customer-supplied water line to the fitting on the end hose supplied, pay
attention to prevent the hose from being twisted or broken.
3. DRAIN CONNECTIONS
- The Ecomiser SU-01 / SU-02 models contain a 1 1/2" (38mm OD) drain hose for end user's
convenience.
- The Ecomiser SU-01 / SU-02 models are factory built with a drain pump. Recommended rough in
height is maximum 18" (457mm).
- Check that the end of the drain hose will empty into a drain with a minimum diameter of 1 1/2"
(38mm).
-
Route the drain hose to the drain. In some cases a grease trap (supplied by others) must be fitted
into the wastewater line. If this trap is required for your installation, check that it is present.
Figure 1-3 Drain Connection
Ecomiser SU-01 / SU-02 Manual – Rev. 06
Max. Height 18" (457mm)
Page 10 of 23

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Ecomiser SU-01

This manual is also suitable for:

Su-02

Table of Contents