4-4 UP/DOWN Buttons
1) Within each mode, it will display time, temperature and selections
2) UP/DOWN buttons will increase or decrease certain variables.
3) When the system is not set in MODE, UP/DOWN buttons will display time remaining in
cycle.
4) When the machine is not running, UP/DOWN button will display wash time duration
(90/120/150 seconds).
4-5 TEMPERATURE LOCK/UNLOCK
While the power is turned OFF, press DOWN + UP + START/STOP button simultaneously for
3 seconds to initiate PCB LINE TEST MODE. Lock/Unlock temperature restriction of 82ºC for
rinse tank, and 50ºC for wash tank
5. Power Breaker ON
1)
Provides power source to the machine. (Breaker ON)
2)
On initial installation startup, when power is provided by the breakers, the machine will make
an initial long buzzer sound.
6. Operation
POWER button will initiate water supply, and as the water level reaches different levels, heaters
will be initiated. The machine will start the initiation stage where water temperature will be heated
up until it reaches the pre-set temperature.
6-1 Initiation Stage
1) If the water temperature in the rinse tank reaches 92ºC (198ºF) and wash tank reaches
55ºC (131ºF), initiation stage is completed. The READY lamp will be turned on.
2) Not meeting the initiation stage requirement:
If the temperature in the upper level rinse tank reaches 92ºC (198ºF), rinse cycle will
initiate once, and if the temperature is below that of 92ºC (198ºF), the machine will not
initiate until this temperature is reached.
6-2 During Initiation Stage
1) Washing, Rinsing, Detergent: 10 seconds
2) Washing: 80 seconds
3) Rinsing: 10 seconds
4) If the door is opened during initiation stage, it will cancel the cycle.
5) Press POWER button to stop the initiation stage.
6) If initiation stage is cancelled, [RUN]/[00],[00]/[00] message will appear in 2 second
intervals.
For example:
[run / 100]: Cycle time: 100 seconds
[65 / 90]: Wash tank temperature: 65ºC, Rinse tank temperature: 90ºC
6-3 POWER OFF
1) Water will start to drain out.
- Drain pump: 90 seconds
- Rinse pump (cleaning process): 10 seconds
- Wait: 10 seconds
- Drain pump re-initiation: ON (30 seconds)  OFF (5 seconds)  ON (5 seconds) 
OFF (5 seconds)  ON (5 seconds)
2) Press START/STOP button during water drain stage to stop the cycle and the machine
completely.