Testing Procedures; Equipment; Charge Mode; Figure 4-1. Bq25180 Evm Connections - Texas Instruments BQ25180 User Manual

Evm
Hide thumbs Also See for BQ25180:
Table of Contents

Advertisement

www.ti.com

4 Testing Procedures

4.1 Equipment

This section includes a list of supplies required to perform tests on this EVM
1. Two Power Supplies: Keithley 2400 Powersupply or equivalent
a. Power Supply #1 (PS #1) will be used as input voltage
b. Power Supply #2 (PS #2) will be used as battery voltage
2. 4 Channel Oscilloscope: To monitor voltages at VIN, VBAT, and VSYS
a. Channel 1 (SC #1) will be used to probe VIN
b. Channel 2 (SC #2) will be used to probe VBAT
c. Channel 3 (SC #3) will be used to probe VSYS
3. Computer: A computer with at least one USB port and a USB cable
4. PC communication interface:
5. Software: Download the

4.2 Charge Mode

Connect the equipment as the following:
Power Supply PS#1: VIN of the BQ25180 at 5V
Power supply PS#2: VBAT of the BQ25180 at 3.7V
Scope Channel SC#1: VIN
Scope Channel SC#2: VSYS
Scope Channel SC#3: VBAT
Turn ON the supply PS#2, then turn ON the supply PS#1. The VSYS will rise to the level of 4.5V. The device will
begin to charge as long as the TS is left at default configuration and there are no other faults.
VIN
USB2ANY connec
To adjust the charge current or change other parameters, connect the USB2ANY to the EVM and then startup TI
Charger GUI.
SLUUCH5A – AUGUST 2021 – REVISED JANUARY 2022
Submit Document Feedback
USB2ANY
with the latest firmware
TI Charger GUI
from Texas Instruments.
o n
VDD connec on
¢

Figure 4-1. BQ25180 EVM Connections

Copyright © 2022 Texas Instruments Incorporated
Testing Procedures
VBAT
TS/MR Pushbu
o n
¡
BQ25180 EVM User's Guide
5