ELECTRONIC CONTROL UNIT LRX 2197
Single-phase electronic control unit for the automation of rolling
shutters with incorporated radio receiver.
- Mod. LG 2197
- Mod. ( LR
2197 )
- Mod. ( LR 2197 / 330 )
- Mod. ( LR 2197 / 418 )
- Mod. LRS 2197
- Mod. LRS 2197 SET
- Mod. LRH 2197
(
) Product intended for those countries where its use is
permitted
TECHNICAL DATA:
- Power supply
- Flashing beacon output
- Motor output
- Photoelectric cells power supply : 24 V a/c 3 W max.
- Low voltage safety features and commands : 24 V c/c
- Operating temperature
- Radio receiver
- Op. transmitters
- Max stored TX codes
- Box dimensions
- Container
TERMINAL BOARD CONNECTIONS:
CN1:
1 : 230 V a/c line input (Phase).
2 : 230 V a/c line input (Neutral).
3 : Clean contact output for Flashing Beacon/Courtesy Light.
4 : Clean contact output for Flashing Beacon/Courtesy Light.
5 : Opening motor output.
6 : Shared motor output.
7 : Closing motor output.
CN2:
1 : Photoelectric cell control and power supply (24 V a/c).
2 : Photoelectric cell control and power supply (GND).
3 : PUL open-close command button input (NA).
4 : Shared GND input.
5 : DS1 safety device input.
6 : DS2 safety device input.
7 : Shared GND input.
8 : DS3 safety device input.
9 : Earth antenna input.
10 : Antenna hot pole input.
OPERATIONAL DATA:
Operation with push-button station:
The following operation is obtained using the low voltage push-
button station (PUL) to control the shutter:
the first press opens the shutter until the end of the motor timer
and the second press closes it; if pressed again before the end
of the motor time, the control unit stops movement whether the
shutter is opening or closing.
A further command restarts motion in the opposite direction.
Operation using different models of Radio Control:
Different models of radio control may be programmed: by
storing a code (1 button) a cyclic step by step operation (Open
- Stop - Close) may be achieved, and by storing two different
codes (2 buttons) separate commands are created, one for
opening and one for closing. Storing three different codes (3
"BeFree" series buttons) produces three distinct commands:
the first for Open, the second for Stop and the third for Close.
: Without radio receiver
: 306
Mhz
: 330
Mhz
: 418
Mhz
: 433.92
Mhz
: 433.92 Mhz narrow band
: 868.3 Mhz narrow band
: 230 V a/c 50-60 Hz 1100 W max.
: 230 V a/c 500 W max.
: 230 V a/c 500 W max.
: -10 to 70 ° C
: see model
: 12-18 Bit or Rolling Code
: 75
: 110 x 121 x 47 mm.
: ABS V-0 (IP54).
GB
Operation using a 1-button radio control:
The following type of operation is obtained using a radio control
with a single button: the first press controls the opening
movement of the shutter until the motor timer stops. The
second press controls the closing movement of the shutter. If
the button is pressed before the motor stops running, the
control unit will stop the shutter moving and the button will need
to be pressed again to reactivate the motor in the opposite
direction.
Operation using a 2-button radio control:
The following type of operation is obtained using a radio control
with 2 buttons: the first button ("Up", corresponding to the
opening movement) controls opening until the motor stops
running and the second button ("Down", corresponding to the
closing movement) controls the Closure of the shutter. If the
opening movement is interrupted with another "Up" command,
the motor will continue to run in the upward movement
direction. If, however, the movement is interrupted with a
"Down" command, the control unit will stop the motor.
The procedure is the same for the closing movement phase.
Operation using a 3-button radio control (BeFree series):
The following type of operation is obtained using a radio control
from the BeFree series: the Up button controls the opening
movement until the set motor time has elapsed, the Stop button
makes the shutter stop and the Down button controls the
closure of the shutter. If a stop command is sent during the
opening or closing movement, the control unit causes this
movement to stop. If a command which is the opposite
direction to the current movement is sent during the opening or
closing movement, the control unit causes the shutter to
change direction.
Automatic closing:
The control unit can close the shutter automatically without
sending additional commands.
The selection of this operation mode is described in the Pause
Time programming mode.
DS1 safety device:
The DS1 input anticipates the connection of a general safety
device with contact (NC). If not used, this input must be
bridged.
Action is not taken into account during the opening stage but
causes inverted motor action during the closing stage. Another
safety device operating mode is described in the SEL DS1
Programming section.
DS2 safety device:
The DS2 input anticipates the connection of a general safety
device with contact (NC). If not used, this input must be
bridged.
Action is not taken into account during the opening stage but
causes inverted motor action during the closing stage. Another
safety device operating mode is described in the SEL DS2
Programming section.
DS3 safety device:
The DS3 input anticipates the connection of a general safety
device with contact (NC). If not used, this input must be
bridged.
Action is not taken into account during the opening stage but
causes inverted motor action during the closing stage. Another
safety device operating mode is described in the SEL DS3
Programming section.
Operation with TIMER:
The control unit may be connected to a timer instead of using
the open-close command button (PUL).
Example: at 8:00 a.m. the timer closes the contact and the
control unit opens the shutter; at 6:00 p.m. the timer opens the
contact and the control unit closes the shutter. Between 8:00
a.m. and 6:00 p.m. at the end of the opening phase, the control

Advertisement

loading

Summary of Contents for Seav LR 2197 Series

  • Page 1 Operation using a 1-button radio control: ELECTRONIC CONTROL UNIT LRX 2197 The following type of operation is obtained using a radio control with a single button: the first press controls the opening Single-phase electronic control unit for the automation of rolling movement of the shutter until the motor timer stops.
  • Page 2 unit disables the flashing beacon, the automatic closing stage 2) INB. CMD. AP: (command inhibition during opening and and the radio controls. pause time, if entered) The command inhibition function during opening and pause time, if entered, is used when automation includes the loop PROGRAMMING: detector.
  • Page 3: Extended Menu

    button again for a moment; the automatic closing time is stored The control unit allows the transmission code to be and the T. PAUSA LED remains lit in a constant manner. programmed by remote, without using the SEL button. To restore the initial configuration (without automatic closing) To programme the transmission code remotely proceed as navigate to T.PAUSA when the corresponding LED is flashing follows: send the radio control code continuously for more than...
  • Page 4: Hardware Diagnostics

    flash alternatively), using the “SEL” button navigate to PAUSA control unit may be switched on again. The error status is reset LED when flashing and press the “SET” button: at that moment and the control unit is ready to operate normally. the PAUSA LED lights up in a constant manner and programming is completed.
  • Page 5: Notes For The Installer

    We advise that you also take note of the following OTES FOR THE NSTALLER recommendations: The control unit was designed to facilitate the task of − Before shutter automation, it is necessary to check the automating closure while respecting the guidelines set out in product is in good condition and that it complies with EN the Machines Directive and the CPD.
  • Page 6 The below products: Electronic Control Unit: OR THE MPORTANT LG 2197 - LRS 2197 - LRS 2197 SET - LRH 2197 - The device should not be used by children or by individuals conform to the specifications in the Directives with reduced physical or psychological abilities unless R&TTE 99/5/EC, EMC 2004/108/EC, LVD 2006/95/EC.

This manual is also suitable for:

Lrs 2197Lrs 2197 setLrh 2197Lr 2197/330Lr 2197/418Lg 2197