LRX 2102 NEW ELECTRONIC
CONTROL UNIT
Single-phase electronic control unit for the automation of sliding
gates, doors and barriers with integrated radio receiver.
Equipped with initial motor boost, motor power adjustment and
deceleration power adjustment, electronic brake, pedestrian
passage, dead man and several other functions, all easily
selectable by the installer manually or via Smartphone using the
BW 2356 interface with which it will be possible to configure the
control unit, through the BeTech APP (Bluetooth), furthermore
the user has the possibility to send commands not only from the
radio control and push button panel but also from a Smartphone
through the BeLite APP (Bluetooth) or the BeAll APP (Wi-Fi ).
- Mod. LG 2102 New
- Mod. LS 2102 SET New
- Mod. LH 2102 New
I
MPORTANT FOR THE USER
- The device can be used by children over 8 years of age
and persons with reduced physical or psychological
abilities or with little knowledge and experience only if
supervised or educated in its operation and safe use, in
order to also understand the dangers involved in its use.
- these instructions are also available at the website
www.seav.com
- Do not allow children to play with the device and keep
the radio controls away from their reach.
- Frequently examine the system to detect any signs of
damage. Do not use the device if it is in need of repair
work.
-Always remember to disconnect the power supply before
carrying out any cleaning or maintenance.
-If you use a dead-man control button, make sure other
people are away.
- Cleaning and maintenance must not be carried out by
unsupervised children.
ATTENTION: keep this instruction manual safe and
observe the important safety requirements contained
herein. Failure to comply with the requirements may
cause damage and serious accidents.
I
MPORTANT FOR THE INSTALLER
1) Before automating the gate, check that it is in good
conditions, in compliance with the Machinery Directive
and with EN 12604.
2) Check that the location where the installation is
located enables compliance with operating temperature
limits specified for the device.
3) The safety of the final installation and compliance
with all prescribed Standards (EN 12453 - EN 12445) is
the responsibility of the person who assembles the
various parts to construct a total closing.
4) It's recommended to use safety devices with a
connection self test.
5) Once installation is finished, it is recommended that
all
necessary
checks
programming of the control panel and correct installation
of safety devices) to ensure that compliant installation
has been performed.
: Without radio receiver
: 433,92 Mhz "narrow band"
: 868,3 Mhz "narrow band"
be
performed
(appropriate
GB
6) Fix the control unit to the wall using the appropriate
support. This support should be facing downwards:
insert the screws in the spaces provided.
7) The control unit does not have any type of isolating
device for the 230 Vac line. It is therefore the
responsibility of the installer to set up an isolating device
inside the system. It is necessary to install an omnipolar
switch, surge category III. It must be positioned to
provide protection from accidental closing, pursuant to
point 5.2.9 of EN 12453.
8) Cables for power and connection to the motor
suitable for insertion in the pg9 cable glands provided
must have an outside diameter between 4.5 and 7 mm.
The internal conductor wires must have a nominal
section of 0.75mm2 of H05VV-F material. If a raceway is
not used, use H05RR-F cables. Pay careful attention
when fastening the cables so that they are anchored in a
stable manner. Furthermore, care is required when
drilling holes in the outside casing where connecting and
power supply cables will pass, and when assembling the
cable glands, so that everything is installed so as to
maintain the panel's IP protection characteristics.
9) The gearmotor used to move the frame must comply
with that prescribed at point 5.2.7 of EN 12453.
In compliance with 5.4.2 of EN 12453, it is
10)
recommended to use gearmotors equipped with an
electric-mechanical release device, so that the door can
be moved manually in case of necessity.
11)
In compliance with 5.4.3. of EN 12453, use electric-
mechanical release systems or similar devices which stop the
door safely in the end run position.
12) The various electrical components external to the
control unit must be cabled in accordance with standard
EN 60204-1 as amended, and as set forth in point 5.2.7
of EN 12453. Power supply and connection cables must
be fixed using the cable glands provided.
13) The assembly of a pushbutton panel for manual
control must be done by positioning the push button
panel at a minimum height of 1.5m not accessible to the
public and so that the user does not find himself in a
dangerous position.
14) The safety function ensured by the control unit is
active only during closing, therefore, protection on
opening must be ensured in the installation phase with
measures (guards or safety distances) independent of
the control circuit.
15) For proper functioning of the radio receiver, if using
one or more control units, the installation at a minimum
distance of at least 3 metres one from the other is
recommended.
1
rev. 1.0 09/04/2024

Advertisement

loading

Summary of Contents for Seav LRX 2102

  • Page 1 LRX 2102 NEW ELECTRONIC 6) Fix the control unit to the wall using the appropriate support. This support should be facing downwards: CONTROL UNIT insert the screws in the spaces provided. 7) The control unit does not have any type of isolating Single-phase electronic control unit for the automation of sliding device for the 230 Vac line.
  • Page 2: Technical Data

    Technical data : Operating features : - Power supply : 230 Vac 50/60Hz 900W (4A) max. Step-by-step operation: - Flashing beacon output : 230 Vac 50-60 Hz By using either the radio-control ( CODE led on ) or the low 100W Resistive/50W Inductive Load max.
  • Page 3 (making the LAMP/CORT LED flash rapidly). Repeat the IMPORTANT: If the control unit has been previously operation if you wish to restore the factory setting. programmed through SEAV "BeTech (Bluetooth)" application and covered by a password, the SEL and SET keys 5) PGM. AUT. : (Automatic Programming):...
  • Page 4: Extended Menu

    8) T. PAUSA : C) IN. CMD. AP. ( Dead man Function ) : (Automatic closing time programming max. 4 minutes) The control unit is supplied by the manufacturer with the Dead The control unit is factory supplied without automatic closing. man function disabled.
  • Page 5 Smartphone, thanks to 5 seconds, after which amount of time the T. MOT. PED and T. the SEAV "BeTech (Bluetooth)" application. PAUSA LEDs will flash simultaneously. The user then has 30 The application allows the installer to have a...