BLUE LED is flashing
The buzzer emits
a continuous sound
BLUE and RED LEDS
are flashing alternately
Impossible to arm the machine
BLUE LED doesn't switch on
Cannot arm,
BLUE LED doesn not
become on
When you press the reset
cylinder's button you don't hear
the sound of the buzzer,
the frontal LED are flashing but
the RED LED does not reset
The cylinder does not enter
The cylinder doesn't go out
Setting the shooting time, the
buzzer does not sound and
the LEDs do not flash
21
Wiring error
Overvoltage power line
(110/220 V)
Overtemperature of the PCB
Disturbance/ interference
or potential differences
between devices
Error in the thermal loop
Wiring error
Wiring error
The Jumper P3 is in the
"SET" position
The plate is raised
The cylinder is stuck
in the valve
The jumper P3 stands in
the "RESET" position
Verify that the alarm, once activated has tension on
connectors of at least 12 V between GND(5) + SHOOTS(4)
Try to reset. See paragraph 13. In case of unsuccessful
restore the PCB can be damaged, contact the assistance
service.
Check there is a sufficient ventilation around the machine.
See paragraph 15. To reset see paragraph 15
In the case of strong interference (lightning) can occur a
thermocouple reading error, make a reset.
See paragraph 15. In case of unsuccessful restore can be
occurred a potential difference or a fault.
In large size plants or with more than on fogging system
connected with the same central, in rare situations, it may
occur that there are potential differences between the
equipments and it could be necessary to uncouple.
Possible fault of: thermocouple, resistance or fuse
cable. Don't try to repair
Contact the assistance service center.
Test the terminal that there is a minimum voltage
of between 11V - GND (5) + ARM (3),
when the anti-theft system is activated
Test the terminal that there is a minimum voltage
of between 11V - GND (5) + ARM (3),
when the anti-theft system is activated
Warning in this case
shooting time is reset to zero
Cylinder reset - Paragraph 13
Shooting time setting - Paragraph 11
Pressure down and then pull
Pressure down and then pull
See the setting mode of the shooting
time at paragraph 11