N.B. To correctly dimension the machines it is needed to verify that the saturation of the area occurs in
faster time than the one supposed for the theft.
SHOOTING TABLE
Seconds
to protect
of emission
15-18 (64*)
29-35 (105*)
44-52 (156*)
58-70 (210*)
73-87 (261*)
SHOOTING TABLE
Seconds
to protect
of emission
19-23 (69*)
38-46 (138*)
57-68 (204*)
77-92 (276*)
96-115 (345*)
115-138 (414*)
135-162 (486*)
160-192 (576*)
175-210 (630*)
*
Industrial standard as from other manufacturers
The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the second
column. The value in m³ varies depending on the density to be obtained. Within the second column, the first value allows to get the
maximum density recommended to ensure the absence of any residual, while with the second value you get minimum recommended
visibility of according to the standard CENELEC, whereas a higher visibility would make the fog superfluous. In places where a little residual
causes no problems, it is possible to increase the shooting time. Please note that the higher the fog released, the more the time required
to recover visibility. High levels of fog, over recommended limits, can leave residual.
Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in water, it is enough to use a wet cloth for cleaning.
If you desire to obtain an average of 1 meter visibility after 60 seconds, as specified by the standard, as used as reference by all
manufacturers of Fog generators, the number of shooting seconds must be reduced by half.
WARNING! After the fog emission, and for a few minutes the nozzle is very
hot RISK OF BURNS IF TOUCHED by bare hands.
15
FAST 03 PRO PLUS
to protect
1
87-105 (315*)
2
102-122 (366*)
3
116-140 (420*)
4
131-157 (471*)
5
146-175 (525*)
FAST 02 PRO PLUS
to protect
1
190-228 (684*)
2
205-246 (738*)
3
220-264 (792*)
4
235-282 (846*)
5
250-300 (900*)
6
265-318 (954*)
7
280-336 (1008*)
8
295-354 (1062*)
9
310-372 (1116*)
FOG FLOW DIRECTION
To ensure the right direction of the fog flow, it is recommended to insert a screwdriver of the
diameter of the hole and, without forcing, orient the nozzle in the correct fog emission direction.
This allows you to clearly see the direction and keep it in place while
tightening.
To screw and unscrew the nozzle you should use a pair of pliers in good condition to avoid damaging
the plating. Do not overscrew the nozzle, it is sufficient that the teflon nozzle does not move.
Do not direct the fog jet towards objects and walls less than 2 meters away or to the floor if it is
installed at a height lower than 2.50 meters (we advise against the installation on the floor).
(2C and 1C)
Seconds
of emission
6
7
8
9
10
Seconds
of emission
10
11
12
13
14
15
16
17
18
Seconds
to protect
of emission
160-192 (576*)
175-210 (630*)
189-227 (681*)
204-244 (732*)
218-262 (786*)
Seconds
to protect
of emission
325-390 (1170*)
340-408 (1224*)
355-426 (1278*)
370-444 (1332*)
385-462 (1386*)
400-480 (1440*)
415-498 (1494*)
11
12
13
14
15
19
20
21
22
23
24
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fast 03 2c pro plusFast 02 2c pro plus

Table of Contents