14 August 1997
6. ENERGY SAVER AND ENERGY STAR
The energy star and energy saver functions are the same as for the A133
machine. The programming modes for these energy saver functions are as
follows.
- 115V machine -
Mode
Auto off timer
Low power timer
Recovery time from
the low power mode
Duplex priority
Auto off mode
- 230V machine -
Mode
Auto off timer
Low power timer
Recovery time from
the low power mode
Duplex priority
Auto off mode
All manuals and user guides at all-guides.com
Method
Selectable values
UP mode
10 ~ 240 min
UP mode
1 ~ 240 min
SP mode
10 s (175ºC)
20 s (162ºC)
30 s (150ºC)
UP mode
1 sided to 1 sided
1 sided to 2 sided
2 sided to 2 sided
SP mode
Enabled
Disabled
Method
Selectable values
This function only works in 115V machines.
UP mode
1 ~ 15 min
SP mode
10 s (175ºC)
20 s (162ºC)
30 s (150ºC)
UP mode
1 sided to 1 sided
1 sided to 2 sided
2 sided to 2 sided
This function only works in 115V machines.
17
FUSING TEMPERATURE CONTROL
Default
60 min
15 min
20 s
(162ºC)
1 sided to
2 sided
Enabled
Default
10 min
20 s
(162ºC)
1 sided to
1 sided
Unit/Step
10 min
1 min
Unit/Step
1 min

Advertisement