CELSIUS / FAHRENHEIT CONVERSION

1. Turn on the power switch(es) for the component(s) that require
temperature unit conversion.
2. Press and hold the Hot Air and Iron $ buttons simultaneously for 3
seconds, the Hot Air display will show A1.
3. Press the Iron $ button and the "C" or "F" will show in the Hot Air
and Iron displays.
4. Press the Hot Air $ button to change to "F" or the Hot Air # button
to change to "C".
5. Once the desired temperature unit is selected, let the unit stand for
5 seconds. The unit will automatically store the selection.
AUTOMATIC VS. MANUAL MODE FOR HOT AIR GUN
The hot air gun has a built in safety feature where every time the
hot air gun is placed in the side holder it will go into Cool Down and
Standby Mode. This ensures that the hot air gun is not left running
for long periods of time causing undo wear on the unit. This is
called Automatic Mode and is enabled for your safety.
The unit does have the option to go into Manual Mode so that the
hot air gun will NOT go into Cool Down and Standby Mode when
placed in the side holder.
ATTENTION: This unit should ALWAYS be used in Automatic mode for
safety purposes. It is very rare that manual mode is needed.
Using Manual mode will also greatly reduce the life of the heating
element in the hot air gun.
1. Turn on the power switches to the component(s).
2. Press and hold the Hot Air and Iron $ buttons simultaneously for 3
seconds, the Hot Air display will show A1.
3. Press the Hot Air $ button to change to "0" (Manual Mode) or the
Hot Air # button to change to "1" (Automatic Mode).
4. Once the desired conversion is selected, let the unit stand for 5
seconds. The unit will automatically store the selection.