Metering Unit - Stihl SR 430 Instruction Manual

Hide thumbs Also See for SR 430:
Table of Contents

Advertisement

English
crops is 4–5 m. Mark the working width with
stakes.
Dividing the distance walked in meters by the
time in minutes gives you the walking speed in
meters per minute (m/min).
Example:
The distance covered in one minute is 10
meters.
Walking speed:
10 m
= 10 m/min
1 min
11.5
Determining discharge rate
The setting of the metering unit is calculated as
follows:
V
(l) x v
(m/min) x b(m)
a
b
2
A (m
)
V
= Quantity of solution
a
v
= Walking speed
b
V
= Discharge rate
c
b = Working width
A = Area
Example:
The values determined above and a working
width of 4 meters require the following setting on
the metering unit:
144 l x 10 (m/min) x 4 m
2
3600 m
Hectares (ha) have to be converted into m
2
10,000 = m
).
To adjust the required discharge rate see "Meter‐
ing Unit".
1)
Standard equipment in some markets or available as special accessory
18

12 Metering Unit

12.1
A
B
= V
(l/min)
c
Solution feed is started and stopped with the
valve lever (1).
► Position A (valve lever vertical, up) – open
► Position B (valve lever horizontal, down) –
12.2
= 1.6 l/min
The scope of supply includes metering knobs
which allow a wide range of different discharge
rates.
2
(ha x
– Standard metering knob (A) with positions 1 to
– ULV metering knob
Valve lever
closed
Metering knobs
A
6
1)
0.8
12 Metering Unit
1
1
B
(B) with positions 0.5 to
0458-454-0121-G

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr 450

Table of Contents