Siemens SIMATIC RF1070R Manual page 29

Hide thumbs Also See for SIMATIC RF1070R:
Table of Contents

Advertisement

5 Useful information
Table 5-7 Response telegram with errors
Byte
Value
0
0x8C
0x9C
1
0x01
2
0x00
3
0x01
4
0x00
5
0x01
6
0xD9
vhl_get_snr: Request the serial number (UID) of the card in the reader's antenna field
Table 5-8 Job telegram
Byte
Value
0
0x0C
0x1C
1
0x01
2
0x01
3...4
0x00
5
0x0D
Table 5-9 Response telegram without errors
Byte
Value
0
0x0C
0x1C
1
0x01
2
0x01
3
0x04
4
0x00
5
0x11
6
0x22
7
0x33
8
0x44
9
0xXX
Reading out UID with SIMATIC RF1070R
Article ID: 109780625,
V1.0,
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length
Status
Possible status codes:
0x01: NOTAG_ERR
0x03: HF_ERR
0x08: CONFCARD_READ
0x0C: HW_ERR
Optional checksum (when the value "0x9C" is set in byte 0)
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length (0 bytes)
Optional checksum (when the value "0x1C" is set in byte 0).
Without checksum
With checksum
DevCode of the command set containing the command to be called.
CmdCode of the command to be called.
Parameter length, depending on card type
Serial number of the card, depending on card type
Optional checksum (when the value "0x1C" is set in byte 0).
09/2020
Description
Description
Description