1 Introduction
Note
Another application example for linking the
SIMATIC RF1040R/RF1070R reader to an S7-1500 station via the RF170C
communication module can be found in the Siemens Industry Online Support
(SIOS) under \4\.
1.2

Principle of operation

Diagram
The following figure schematically illustrates the most important components of the
solution:
Figure 1-2
SIMATIC PLC
Serial coupling/ RS232
RFID System
Implemented functions
The following functions are implemented in the application example:
Parameter assignment for the point-to-point connection of the communication
module CM1241 RS232.
Reset SIMATIC RF1070R reader.
Monitor the antenna field of the RF1070R reader and select the card located
there.
Receive the UID from the SIMATIC RF1070R reader from the CM1241 RS232
communication module and store it in a data block.
Advantages of this solution
Save time and money when commissioning your own automation solution.
Reusable STEP 7 code. This can be easily adapted for extensions.
Note
This application example can also serve as a basis for controlling a SIMATIC
RF1040R/RF1070R reader centrally on an S7-1500 CPU via the CM PtP RS232
BA; or decentralized via an ET 200SP CM PtP.
Reading out UID with SIMATIC RF1070R
Article ID: 109780625,
V1.0,
CM1241 RS232
SIMATIC RF1070R
09/2020
SIMATIC S7-1200
Card with
UID