An Employee-Owned Company SF SERIES WATER SOFTENERS WCC’s “SF” Series softeners feature 1” service connections, heavy duty electronic control valves, high-strength fiberglass-reinforced mineral tanks, and long-lasting synthetic cation resin. This series is perfectly designed for retail spaces, restaurants, commmercial laundry, and office complexes.
Page 7
® ® For a detailed, model-specific specification, please contact WCC (Water Control Corporation). Detailed drawings also available upon request (CAD or Revit Water softening system requires a minimum inlet water pressure of 30 psig and maximum of 120 psig. If resin tank is subject to vacuum, an adequate vacuum relief valve must be properly installed.
Page 12
POWER SUPPLY CONNECTIONS NETWORK/COMMUNICATION CABLES Installing the Power Supply: AND CONNECTIONS NOTE: Power Supply includes a harness with 2 black wires Use a CAT5 or better Network/Communication cable. that connect to circuit board, see page 15. Connect the network/communication cable rst before 1.
FLECK NXT2 CONTROLLER ADVANCED SYSTEM NETWORK CONTROLLER Coated Stock - CMYK FEATURES • BENEFITS Assistance Name and Phone Number On-screen multilingual support: English, Fran ais, Deutsch, Italiano, Español, Nederlands, Error Log History Português Water Usage Daily (up to 13 weeks) Time of day super capacitor Push Settings backup for 12-hour power loss...
Page 15
VALVE SPECIFICATIONS VALVE TYPE 2750 3150 System Type 4, 5, 6, 7, 8, 9, 14 2850 3900 2900s 2815 SPECIFICATIONS SYSTEM SYSTEM DESCRIPTION NUMBER OF TANKS/CONTROLS TYPE Time Clock: No Meter Immediate: One Meter Single Unit Delayed: One Meter Remote: No Meter Immediate: All Meters Interlocked From 2 up to 8...
Page 16
TIMER DISPLAY System Network Valve Flow Status Master Time Number Indicator State Indicator LEDs Indicator of Day Display Screen Blue LED Alternates between On - Unit in Service Date, Flow Rate, and Blinking - Regeneration Queued Volume Remaining (If a regeneration is Green LED queued, displays time On - Unit in Regeneration...
Page 17
TIMER OPERATION Timer Operation During Regeneration In the Regeneration Cycle step display, the timer shows the Setting the Time of Day current regeneration cycle name the valve is in, or has reached, NOTE: Set Time of Day on any unit and the rest of the units in and the time remaining in that step.
Page 18
TIMER FEATURES Remote Lock Regeneration Types The timer does not allow the unit/system to go into Softener/Filter Meter Delayed - When volume remaining Regeneration until the Regeneration Lockout Input signal to the reaches zero and the scheduled regeneration time is reached unit is cleared.
Page 19
TIMER FEATURES continued... Push Settings The ability to transmit settings from one unit to all other connected units. Select the desired Master Programming settings on one unit then push the same settings to all other connected units. After push settings are complete, you may still make unique changes to individual units.
Page 20
SYSTEM DEFINITIONS System 4 - Single Unit System 14 (2-8 Units) Demand Recall Single Tank configuration Time Clock: No Meter Immediate: One Meter input is required on each tank. Unit #1 will begin In Meter Delayed: One Meter Remote Signal Start Service with #2, #3, and #4 (if installed) will begin in Standby.
Page 21
DAY OVERRIDE/TIME-DRIVEN Example: 10 D Range: Off - 99 Days USER PROGRAMMING MODE REGEN. TIME Example: FLOW CHART Range: 0 - 23 Hours 59 Minutes. 02:OOHR User Programming Mode Press and hold the Down and Up buttons simultaneously for 3 seconds to enter User Programming mode.
Page 22
14 H 0 M Last time programming settings were changed. DIAGNOSTIC PROGRAMMING MODE Example: ERROR LOG ERROR LOG EMPTY Record of error events chronologically. FLOW CHART Diagnostic Programming Mode Example: SUN-AVERAGE USAGE Average usage from past Sunday. 29.7 G 1. Press and hold the Left button to enter Diagnostic Programming mode.
Page 23
TIME OF DAY PROGRAMMING MODE FLOW CHART Setting the Time of Day NOTE: Set Time of Day on any unit and the rest of the units in the system will update the Time of Day automatically. 1. Press and hold the Up button for 2 seconds. The "Time"...
An Employee-Owned Company Commercial Water Softener Startup Procedures (TECHNICIAN TO INITIAL EACH ITEM SUCCESSFULLY TESTED.) Date _______________________________________________________________________________________________________________________ Project Name/Location _______________________________________________________________________________________________________ Technician __________________________________________________________________________________________________________________ Model/Serial Number _________________________________________________________________________________________________________ Number/Size of Resin Tanks ___________________________________________________________________________________________________ Size of Brine Tank ____________________________________________________________________________________________________________ Brine Reclaim System ________________________________________________________________________________________________________ ☐ Meter ☐...
Page 25
☐ WCC STARTUP PROCEDURES | PG 2/3 Wire brine reclamation valves (if applicable). ☐ Install communication cables between valves ☐ Plug in all valves to GFCI approved wall receptacle. ☐ Open system bypass and isolate off softener inlets/outlets. Startup ☐ Set time of day on Valve #1.
Page 26
Signature of Installing Contractor I CERTIFY THAT STARTUP AND TRAINING HAVE BEEN COMPLETED PER AGREEMENT. Name: __________________________________________________________________________________________________________________ Company: ________________________________________________________________________________________________________________ Signature: ________________________________________________________________________________________________________________ Date: __________________________________________________________________________________________________________________ Water Control Corporation 7150 143rd Ave NW • Ramsey, MN 55303 Phone: 763-427-9638 • Fax: 763-427-5665 www.watercontrolinc.com...
An Employee-Owned Company Commercial Water Softener Maintenance Procedures (TECHNICIAN TO INITIAL EACH ITEM SUCCESSFULLY TESTED.) Date ___________________________________________________________________________________________________________________ Project Name/Location ___________________________________________________________________________________________________ Technician ______________________________________________________________________________________________________________ Model/Serial Number _____________________________________________________________________________________________________ Pre-Maintenance Audit Checklist ☐ Test Water Quality Levels (Hardness on Cold/Hot) ☐ Check for Blinking Time? Yes ☐ No ☐ ☐...
Page 32
Detected Errors If a communication error is detected, an Error Screen will appear. • All units In Service remain in the In Service position. • All units in Standby go to In Service. • Any unit in Regeneration when the error occurs completes Regeneration and goes to In Service.
FLECK 2750 ® 1-INCH CONTROL VALVE IDEAL FOR RESIDENTIAL OR COMMERCIAL FILTER AND SOFTENER APPLICATIONS FEATURES/BENEFITS Lead-free brass valve body for Time-tested, hydraulically-balanced superior strength and durability piston for service and regeneration Continuous service flow rate of 26 Rugged-built electromechanical GPM with a backwash of 25 GPM timer designed with heavy duty 3/8"...
Page 34
VALVE SPECIFICATIONS DIMENSIONS Valve Material Lead-free brass* Distributor Pilot 1.05" O.D. (26.7 mm) Inlet/Outlet 1" NPTM/BSPM Drain Line 3/4" NPTM Cycles 3 or 5 Brine Valve 1600 or 1650: 3/8" 1700 or 1710: 1/2" FLOW RATES (50 PSI INLET) – VALVE ALONE Injector System 1600 or 1700 Continuous...
Page 35
WATER PURIFICATION STAINLESS STEEL METERS HIGH EFFICIENCY AND TIMELY REGENERATIONS Reduce your SKUs with Pentair’s Stainless Steel Meters. Manufactured with truly lead-free stainless steel materials, SS meters are designed to meet today’s water treatment needs. 1” LEAD FREE DURABLE MATERIALS Truly lead-free 316 grade Rust-resistant stainless steel material...
Page 36
SPECIFICATIONS MAX FLOW RATE PRESSURE DROP K FACTOR *ACCURACY RANGE STANDARD EXTENDED METER TYPE (GPM) FLOW RATE (PSI) (PULSES/GALLON) +/ 5% (GPM) RANGE (GAL) RANGE (GAL) WATER QUALITY SYSTEMS 5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209 1” PADDLE .7-40 310-5,270 1,550-26,350 P: 262.238.4400 | WATERPURIFICATION.PENTAIR.COM | CUSTOMER CARE: 800.279.9404 | tech-support pentair.com...
Page 37
18 Inch Round Brine Tanks Clack's 18 inch blow molded round brine tanks offer a refreshing look in the residential and light commercial brine tank eld. Durable materials and the latest in plastic processing technology provide trouble-free performance. Ultraviolet inhibitors (UVI) are now standard in all tanks except black, which has a natural resistance to the sun's...
Page 38
Commercial/Industrial Rotationally Molded Brine Tanks Commercial and industrial water softeners require a large volume of brine during each regeneration. From a capacity of 95 gallons to 500 gallons, our Rotationally Molded Brine Tanks are built to last. Molded out of durable, chemically resistant high density polyethylene, their ⁄...