Standard Report For Siemens Dpm - Siemens SIMATIC MV500 Operating Instructions Manual

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Image processing
3.2 Code verification
3.2.9.5

Standard report for Siemens DPM

Note
Grades and evaluations in the standard report for Siemens DPM
The standard report for Siemens DPM only contains the grades and evaluations whose quality
characteristics are activated in the WBM.
With the default setting, activated quality characteristics include all characteristics except for
"Symbol contrast" and "Cell size".
Table 3- 14
Field name (String input)
Verification type (Qt)
Evaluation (Qs)
Overall grade (Q0)
Contrast grade (Q1)
Contrast (q1)
Axial non-uniformity grade (Q2)
Axial non-uniformity (q2)
Unused error correction grade (Q4)
Unused error correction (q4)
Cell modulation grade (Q6)
Cell modulation 1 (q6)
Cell modulation 2 (q6)
Print growth grade (Q9)
Print growth X (q9)
Print growth Y (q9)
Cell size grade (Q10)
Cell size (q10)
Center offset grade (Q19)
Center offset (q19)
Size offset grade (Q20)
Size offset (q20)
Border match grade (Q21)
Border match (q21)
Angle of distortion grade (Q22)
Angle of distortion (q22)
ECCLevel (q14)
Height (q15)
Width (q16)
Angle (q17)
72
Output parameters: Siemens DPM
Value
5
If the exposure settings do not comply with the
standard: F
3 (Good), 2 (Fair), 1 (Poor)
4 ... 0
4 ... 0
0 ... 100
4 ... 0
0.00 ... 1.00
4 ... 0
0.00 ... 1.00
4 ... 0
0 ... 100
0 ... 100
4 ... 0
-100 ... 100
-100 ... 100
4 ... 0
0.0 ... 99.9 mil
4 ... 0
0.0 ... 99.9
4 ... 0
0.0 ... 99.9
4 ... 0
0 ... 100
4, 3, 0
-45 ... 45.0
200
0 ... 9.99 inch
0 ... 9.99 inch
0 ... 360°
Operating Instructions, 03/2021, C79000-G8976-C494-05
SIMATIC MV500

Advertisement

Table of Contents
loading

Table of Contents