Siemens SIMATIC MV500 Operating Instructions Manual page 121

Hide thumbs Also See for SIMATIC MV500:
Table of Contents

Advertisement

Communication module cable
You use the CM adapter cable to connect the communication modules (e.g. RF180C and ASM
456) to the optical reader. The communication module cable is pre-fabricated.
Note that when using the power supply via the communication module, you must enable the
setting "Settings > Options > Lighting > Power supply via POU or CM".
Figure 6-3
Table 6- 2
Pin
1
2
3
4
5
6
7
8
Pin assignment ↔ socket/wire color of the cable/signal connector of the optical reader
Industrial Ethernet connecting cable
Connect a PC/PG (for control and operation) to the optical reader using a prefabricated
Ethernet cable.
Attach the Ethernet cable to a switch to connect the optical reader to an S7 controller via
onboard PROFINET IO.
Figure 6-4
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Pin assignment of communication module plug
Communication module cable, M12 (female, 12-pin) / M12 (male, 8-pin)
Wire color
Signal name
White
24 V
Brown
TxD_N
Green
0 V
Yellow
TxD_P
Gray
RxD_P
Pink
RxD_N
Blue
Not connected
Red
Shield
Pin assignment of "X1 LAN1" Ethernet socket (M12, 4-pin) ③
Connection
6.3 Connecting the reader
Meaning
24 V DC power supply
Send data -
0 V DC power supply
Send data +
Received data +
Received data -
--
--