3.3.5 Weights and dimensions

Weight
Width x Height x Depth
Diameter of mounting holes
Table 7: Weights and dimensions

3.3.6 Electrical data

Further information on the electrical system can be found in the chapter Electrical connection (p.49).
Recommended external fuse
Input signal fl ow sensor (optional)
Table 8: Electrical power supply

3.3.7 Operating and ambient conditions

Ambient temperatures
Storage, transport
Operation
Table 9: Ambient temperatures
Air humidity
Storage, transport
Operation
Table 10: Air humidity
Water temperatures
Recommended water temp
Max. water temp
Table 11: Water temperatures
113x159 x105 mm
Voltage
Current
Power consumption
0,9 kg
5,2 mm
Voltage
5-24 VDC
Min.
-10 °C
0 °C
Min.
-
-
Min.
0
-
- 40 -
104 mm
11 -18 VDC
0,02 A (Standby)/1,2 A (Operating)
max. 14 W
2 A
Current
min. 1mA
Max.
+55 °C
+55 °C
Max.
90 %
80 %
Max.
+38 °C
+40 °C
78 mm
Frequency
1-200 Hz