Extinguishing; Work With Room Thermostat; Work With Ambient Temperature Sensor Installed On The Stove; Draught Conditions - Jøtul PF 1230 Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Available languages

Available languages

9�3 EXTINGUISHING
To extinguish the stove, press the
seconds; the flame icon will go dark.
To reignite the stove, it is recommended to wait until it
cools completely�
It is recommended to extinguish the stove according to
the above guidelines, and it must never be shut down by
disconnecting electrical power supply�
9�4 WORK WITH ROOM THERMOSTAT
If the stove is controlled by means of an external
thermostat (or chronothermostat), the fitter must
program configuration 2. In this configuration, the stove
will shut down when the external thermostat trips (open
circuit).
The stove will automatically reignite when the temperature
falls below the value set on the external thermostat
(closed circuit).
At first firing or after extinguishing of the stove by means
of the control panel (
using the control keyboard�
The stove will also shut down if the temperature continues
to rise despite modulation. In this case, the stove will only
start when the difference between the selected and actual
temperature value will be greater than 20°C.
9�5 WORK WITH AMBIENT TEMPERATURE
SENSOR INSTALLED ON THE STOVE
The stove can be fired/extinguished manually or in the
way that is programmed.
The stove modulates its power depending on the ambient
temperature read by the sensor found on the stove (the
stove maintains the set temperature at minimal fuel
consumption).
If the "Eco mode" function is active, instead of
modulating its power, the stove will shut down after
reaching the set temperature and then reignite after
the room temperature drops below the set delta
(see section 10�3)�
The desired room temperature can be set in the
temperature menu
9�6 DRAUGHT CONDITIONS
Work in continuous mode with minimal draught,
particularly during thawing periods (unfavourable
draught), fosters deposition of soot and tar:
• alternate periods with minimum draught with periods
of maximum draught.

10 AVAILABLE FUNCTIONS

10�1 "TIMER" FUNCTION
This function allows for programming and assigning
personalised programs to different days of the week for
the purpose of automatic firing and/or extinguishing of
the stove.
Up to six personalised programs can be set.
The time of firing and extinguishing, as well as the desired
temperature, can be set in every program.
It is possible to assign up to 3 programs to every day of
the week.
Days of the week are designated by numbers from 1 to 7:
Monday = "d1", Tuesday = "d2", etc., Sunday = "d7".
button for several
button), it must be reignited
.
10�1�1 Configuration of programs
a) Using keys
, select the Configuration menu
press
.
b) Select the
item using button
"7"
button
.
c) Select submenu
confirm by pressing button
[2]
d) Using buttons
, scroll through programs
button
, select the program to be modified.
e) The ignition time parameter will start to flash. Change the
parameter using the
f) The minutes parameter will start to flash. Change the
parameter using the
g) The extinguishing time parameter will start to flash. Change
the parameter using the
.
h) The minutes parameter will start to flash. Change the
parameter using the
i) The desired temperature parameter will start to flash.
Change the parameter using the
button
.
j) Press button
, to confirm the setting.
10�1�2 Assigning programs to days of the week
This function makes it possible to assign up to 3 different
programs to a given day.
a) Using keys
, select the Configuration menu
press
.
b) Select the
item using button
"7"
button
.
c) Select submenu
confirm by pressing button
[1]
d) Using buttons
, select the day
programs are to be assigned.
e) Select the program using button
f) The parameter of the first program to be assigned will start
to flash:
or „
P1–P6
OFF
g) Change the parameter using the
button
.
h) The parameter of the second program to be assigned will
start to flash:
or
P1–P6
i) Change the parameter using the
button
.
j) The parameter of the third program to be assigned will start
to flash:
or
P1–P6
"OFF"
k) Change the parameter using the
button
to confirm the setting.
10�1�3 Timer activation/deactivation
a) Using the arrow keys
b) Confirm using button
c) Use buttons
to scroll and select:
timer, or
to deactivate it.
"OFF"
d) Press the
key to confirm the selection.
When the control clock is engaged, the
displayed constantly.
ENGLISH
and confirm by pressing
.
P1–P6
buttons, then press button
buttons, then press button
buttons, then press button
buttons, then press button
buttons, then press
and confirm by pressing
.
to which
[d1]–[d7]
.
" to deactivate it.
buttons, then press
to deactivate it.
"OFF"
buttons, then press
to deactivate it.
buttons, then press
, select the Timer menu
.
to activate the
"ON"
and
. Using
.
.
.
and
;
icon is
15