Operation; Maintenance; Cleaning - Maico ECA 100 ipro RC Installation And Operating Instructions Manual

Small room fans (radio-controlled)
Hide thumbs Also See for ECA 100 ipro RC:
Table of Contents

Advertisement

Available languages

Available languages

10 Operation

4. Press the teach-in button (≥ 5 seconds) until
the LED on the fan lights up once for approx.
1 second.
ð The setting is saved.
10 Operation
ECA 100 ipro RC
The units are switched on/off either on the RLS
RC room air control, with the DS RC radio switch,
or with a window radio contact to be provided by
the customer.
ECA 100 ipro RCH
The unit is barrier-free. Air extraction takes place
according to the automatic humidity function. If
there is little humidity, the unit switches off com-
pletely.
Program
P1
P2
Table 1: Program selection
RLS RC pro-
Sys-
gram for
tem
ECA ...ipro RC/
level 0
KRC/RCH/
KRCH
Pro-
Master Off
gram P1
Slave(
Off
s)
Pro-
Master Off
gram P2
Slave(
Off
s)
Table 2: Single-type system
Power level 1= 78 m³/h
Power level 2= 92 m³/h
(Details with free outlet)
30
Apartment size
30 m² / 50 m² / 70 m²
90 m² / 110 m² / 130² /
140 m²
Sys-
Sys-
Sys-
tem-
tem
tem
stufe1
level 2
level 3
Power
Power
Power
level 1
level 1
level 2
Off
Power
Power
level 1
level 1
Power
Power
Power
level 2
level 1
level 2
Off
Power
Power
level 1
level 2
RLS RC pro-
System
gram for
level 0
mixed sys-
tem ECA ...
ipro RC/RCH
+ ER 100 RC
Pro-
Mas-
Off
gram
ter
P1
ECA
Slave
Off
ECA
Slave
Off
ER
Pro-
Mas-
Off
gram
ter
P2
ECA
Slave
Off
ECA
Slave
Off
ER
Table 3: Mixed system:
ECA: Power level 1 = 78 m³/h / Power level 2 =
92 m³/h
ER: Power level 1 = 35 m³/h / Power level 2 =
60 m³/h / Power level 3 = 100 m³/h
(Details with free outlet)

11 Maintenance

The unit is maintenance-free.

12 Cleaning

Clean fan regularly, especially after it has
not been used for a long time.
NOTICE Risk of damage to unit if incorrect
cleaning agent is used.
Only clean the cover using water.
Do not use aggressive cleaning agents.
NOTICE Lamellae may break if cleaned incor-
rectly.
Be careful when cleaning them.
Do not open, close or bend the lamellae too
much.
1. Only use a dry cloth to clean the internal parts
of the fan.
2. If the cover is very dirty, carefully remove it
and clean with water.
Sys-
Sys-
Sys-
tem
tem
tem
level 1
level 2
level 3
Power
Power
Power
level 1
level 1
level 2
Power
Power
Power
level 0
level 1
level 1
Power
Power
Power
level 1
level 1
level 2
Power
Power
Power
level 2
level 1
level 2
Power
Power
Power
level 0
level 1
level 2
Power
Power
Power
level 1
level 2
level 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eca 100 ipro rch

Table of Contents