Front Blower (part # 99000132) -Optional

To Switch the Power Cord to the Left Side:

The power cord is installed on the right side from the factory. If you would rather have the cord on the left side of
the blower assembly, use a pair of slip-joint pliers to disconnect the strain relief which holds the power cord in
place. With the power cord slackened, the Molex connectors that attach the power cord to the blower assembly
may be disconnected. Pry the push plug from the left side of the blower assembly and insert it into the hole on
the right side. Pull the left side Molex connector out from behind the deflection plate and cut the nylon tie that
holds the wire back. Insert the Molex connector on the power cord through the hole on the left side of the blower
assembly and attach it to the left side Molex connector. Route the wire directly behind the blower cage. Place the
strain-relief over the power cord (it should be in the same location on the power cord as before – approximately 2"
from where the wires split). Insert the strain-relief into the hole on the left side until the strain-relief locks in place.
Make sure the power cord, wires, or Molex assembly do not interfere with the movement of the impellers.
Remove the strain relief by
squeezing it from the top and
bottom with a pair of pliers.

Installation

1. Use a 3/8" nut driver to remove the
(2) mounting bolts from the front of
the insert
© Travis Industries
Optional Equipment
Disconnect the Molex plug inside the blower
assembly. Remove the power cord by pulling
it out of the hole exposed by removing the
strain relief.
11/5/2021 - 1560
Remove the push plug from
the left side and insert it into
the hole on the right side.