Lopi Evergreen NexGen-Fyre Insert Manual page 41

Table of Contents

Advertisement

2. Remove the (2) Phillips head
screws that secure the rheostat
mounting plate to the blower
assembly (set the screws aside
for reinstallation). Lift the
rheostat mounting plate out of
the way but leave the wires
connected. You will now see
the (2) holes on the blower
assembly used to mount the
assembly.
3. Place the blower assembly into
position under the ashlip of the
insert. Align the mounting holes
in the blower assembly with the
holes in the insert. Secure the
blower assembly to the insert
using the mounting bolts
removed in step 1.
NOTE: Before tightening the screws with a 3/8" nut driver, lift the blower up so it tucks underneath the ashlip
and make sure no wires will be pinched.
4. Put the rheostat mounting plate
back in place and secure it to
the blower assembly using the
(2) Phillips screws removed in
step 2.
5. Plug the power cord running from the blower into a grounded 110-volt electrical outlet.
© Travis Industries
Optional Equipment
11/5/2021 - 1560
41
Evergreen Insert

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents